Installation manual
M1G Installation and Programming
Page 33
CT01:=00600 secr
BurgDuration
CT02:=00000 secr
FireDuration
Menu 06 - Alarm Duration Timers
06-Alarm Cutoff r
Timers
Alarm Cutoff Timers Description of Option
††† Burglar Alarm duration time in seconds. Default time is 00600 sec. (10 min.). Burglar
always activates Siren/Voice Output (Out1) and Siren Output (Out2). Additional outputs
may be programmed using the RP software “Rules” function.
Fire Alarm duration time in seconds. Default time is 65535 sec. (never cutoff). Fire always
activates Siren/Voice Output (Out1) and Siren Output (Out2). Additional outputs may be
programmed using the RP software “Rules” function.
Medical Alarm duration time in seconds. Default is 00600 sec. (10 min.). Medical always
activates Siren/Voice Output (Out1) and Siren Output (Out2). Additional outputs may be
programmed using the RP software “Rules” function.
Audible Police Alarm duration time in seconds. Default time is 00600 sec. (10 min).
Audible Police always activates Siren/Voice Output (Out1) and Siren Output (Out2).
Additional outputs may be programmed using the RP software “Rules” function.
CO (Carbon Monoxide) Alarm duration time in seconds. The default time is 00600 sec. (10
min.). This alarm type is not preassigned to any outputs. The RP software “Rules”
function must be used to assign outputs.
Emergency Alarm duration time in seconds. The default time is 00600 sec. (10 min.).
This alarm type is not preassigned to any outputs. The RP software “Rules” function must
be used to assign outputs.
Freeze Alarm duration time in seconds. The default time is 00600 sec. (10 min.). This
alarm type is not preassigned to any outputs. The RP software “Rules” function must be
used to assign outputs.
Gas Alarm duration time in seconds. The default time is 00600 sec. (10 min.). This alarm
type is not preassigned to any outputs. The RP software “Rules” function must be used
to assign outputs.
Heat Alarm duration time in seconds. The default time is 00600 sec. (10 min.). This alarm
type is not preassigned to any outputs. The RP software “Rules” function must be used
to assign outputs.
Water Alarm duration time in seconds. The default time is 00600 sec. (10 min.). This
alarm type is not preassigned to any outputs. The RP software “Rules” function must be
used to assign outputs.
Aux 1 Alarm duration time in seconds. The default time is 00600 sec. (10 min.). This
alarm type is not preassigned to any outputs. The RP software “Rules” function must be
used to assign outputs.
Aux 2 Alarm duration time in seconds. The default time is 00600 sec. (10 min.). This
alarm type is not preassigned to any outputs. The RP software “Rules” function must be
used to assign outputs.
CT03:=00600 secr
Med Duration
CT04:=00600 secr
Pol Duration
Each alarm type has a cutoff timer. Any output(s) activated by the alarm type will turn off when the cutoff timer expires.
If multiple alarm types are assigned to a single output, all alarms must turn off before the output can turn off. Range is
00000 to 65535 seconds. 00000=Never turn on. 65535=Never turn off NOTE: 65535 sec = 1,092 minutes or 18.2 hrs.
CT05:=00600 secr
CO Duration
CT06:=00600 secr
EmerDuration
CT07:=00600 secr
FrezDuration
CT08:=00600 secr
Gas Duration
CT09:=00600 secr
HeatDuration
CT10:=00600 secr
WatrDuration
Press RIGHT arrow key to select this menu. Press UP or DOWN arrow keys to select
another menu. The ELK key backs up one menu level. To exit press the * or Exit key.
CT11:=00600 secr
Aux1Duration
CT12:=00600 secr
Aux2Duration
††† See Appendix F for UL & ULC Requirements