Instruction Manual
-2-
elkhome.com
11. Twist end of house lead wire (black) and end
of xture lead wire together. Twist wire nut (C)
onto ends of wires. Completely tighten wire nut
(C). Twist end of house neutral wire (white) and
end of xture neutral wire together. Twist wire
nut (C) onto ends of wires. Completely tighten
wire nut (C). Reference chart to the right for
correct wire connections.
12. Wrap electrical tape (not included) around wire
nuts (C) and wires. Ensure wires are securely
fastened into wire nuts.
13. Carefully push all wires and wire nuts into
junction box.
9. Strip 3/4” of insulation from ends of xture
wires.
10. Slightly loosen ground screw on mounting
bracket (A). Do not completely remove ground
screw. Wrap house ground wire (copper) around
ground screw, leaving enough ground wire
to attach to xture ground wire. Twist end of
xture ground wire and end of house ground
wire together. Twist wire nut (C) onto ends of
wires. Completely tighten wire nut (C). Reference
chart below for correct wire connections.
ITEM#: 82192/3
FIXTURE LEAD WIRE HOUSE LEAD WIRE
(BLACK)
FIXTURE GROUND
WIRE
HOUSE GROUND
WIRE (COPPER)
FIXTURE NEUTRAL
WIRE
HOUSE NEUTRAL WIRE
(WHITE)
Connect Black Lead
Supply (House) Wire to:
Connect White Neutral
Supply (House) Wire to:
Black Wire or,
*Parallel Cord
(Round and Smooth) or,
Insulated Wire
(other than green)
with Copper Conductor.
White Wire or,
*Parallel Cord
(Square and Ridged) or,
Insulated Wire
(other than green)
with Silver Conductor.
*When parallel wire (SPT 1 & SPT 2) is used:
The lead wire is round in shape or smooth.
The neutral wire is square in shape or ridged.
No printed words on
wire insulation or,
Printed words on
wire insulation or,
GROUND
SCREW
A
HOUSE GROUND
WIRE (COPPER)
FIXTURE
GROUND
WIRE
C
Connect Supply (House) Ground Copper Wire to:
Bare Copper Wire or,
Bare Silver Wire or,
Green Insulated Wire.