Product data

electric gate operators
section 02829
c. Provide 912B relay module.
7. Heater: Chamberlain / LiftMaster 6532449 Thermostat Control Heater, Fin Type;
designed to automatically maintain a suitable temperature inside a control enclosure
down to -40 degrees F (-40 degrees C). Adjustable from 30 degrees to 120 degrees F (0
degrees to 50 degrees C). Used on operators 115V and 575V.
8. Heater: Chamberlain / LiftMaster 6532448 Thermostat Control Heater, Fin Type;
designed to automatically maintain a suitable temperature inside a control enclosure
down to -40 degrees F (-40 degrees C). Adjustable from 30 degrees to 120 degrees F (0
degrees to 50 degrees C). Used on operators 208V - 460V.
9. Pedestals: PED42 Pedestal; 42 inches (1067 mm) high; mounts to pre-existing concrete
pad; 11 gauge steel construction; power coated black; 2 inch x 2 inch (51 mm x 51 mm)
square post; faceplate with universal hole pattern. Includes hardware.
10. Pedestals: PED4272 Dual height Pedestal; 42 and 72 inches high; mounts to pre-
existing concrete pad; 11 gauge steel construction; power coated black; 2 inch x 2 inch
(51 mm x 51 mm) square post; faceplate with universal hole pattern. Includes hardware.
11. Emergency: Chamberlain / LiftMaster ACP17 Fire Access Box.
B. UL Classification:
1. Conforms to Class I, when tested in accordance with UL325
2. Conforms to Class II, when tested in accordance with UL325.
3. Conforms to Class III, when tested in accordance with UL325.
4. Conforms to Class IV, when tested in accordance with UL325.
C. Operator Enclosure: Fully enclosed, NEMA 3R, weather-resistant, hinged, lockable, 16-gauge
steel enclosure with baked-on high durability powdercoat nish over a 7 gauge steel frame.
D. Operator Motor:
1. 1/2 HP Continuous Duty motor with built-in overload protection for gates up to 1100
lbs. (499 kg) and 45 ft (13716 mm). (14 m) overhead or 25 ft. (8 m) cantilever in length.
a. 115 VAC 60 Hz Single Phase operation.
b. 208 VAC 60 Hz Single Phase operation.
c. 230 VAC 60 Hz Single Phase operation.
2. 1 HP Continuous Duty motor with built-in overload protection for gates up to 1700 lbs.
(771 kg) and 70 ft. (21 m) overhead or 35 ft. (11 m) cantilever in length.
a. 208 VAC 60 Hz Three Phase operation.
b. 230 VAC 60 Hz Three Phase operation.
c. 460 VAC 60 Hz Three Phase operation.
d. 575 VAC 60 Hz Three Phase operation
3. 2 HP Continuous Duty motor with built-in overload protection for gates up to 2500 lbs.
(1334 kg) and 90 ft. (27 m) overhead or 45 ft (13716 mm). (14 m) cantilever in length.
a. 208 VAC 60 Hz Three Phase operation.
b. 230 VAC 60 Hz Three Phase operation.
c. 460 VAC 60 Hz Three Phase operation.
d. 575 VAC 60 Hz Three Phase operation.
E. Gear Reduction: 20:1 gear reduction using worm-gear in synthetic oil bath with a solenoid-
activated brake system that prevents back-driving.