Product data

electric gate operators
section 02829
voltage control, external spike and surge protection, separate open and close external sensor
inputs, fully adjustable inherent obstruction detection system, dual gate operation, built-in radio
receiver, and optional external devices including loop detectors and telephone entry systems.
G. Additional Required Controls:
1. Internally-mounted RF receiver tuned at 315 MHz.
2. Inherent obstruction sensing providing separate, single force adjustments for both open
and closed directions, allowing a closing gate to reverse to the opposite limit and stop
when encountering an obstruction.
3. External obstruction sensing providing separate open and close cycle input connections
for external contact and non-contact sensors.
4. Maglock control relay to activate and deactivate an optional magnetic lock for securing
the gate.
5. UL 325-compliant entrapment warning alarm system providing ability to offer a warning
tone which begins 3-seconds prior to gate movement and continues during gate
operation.
6. Loop detector inputs allowing for the connection of exit, shadow, and interrupt loop
detectors.
7. Control wiring distance can exceed 1,000 feet (305 meters) to allow exibility of gate
operator placement.
8. Dual gate operation 2-wire control system that provides for the operation of two separate
gate operators in unison at a single entrance and also provides the ability to connect
accessories to either operator.
9. Automatic Closing Timer: Timer-to-close providing adjustable timer settings between 1
and 180 seconds which resets upon receiving any additional open commands.
10. Sequenced Access Management System providing ability to control a slide gate operator
in tandem with a barrier gate operator.
11. Maximum run timer to protect gate and operator from damage by limiting run time to 120
seconds.
H. Emergency Release: External manual hydraulic release for manual operation of gate during
emergencies and maintenance work.
I. Emergency Stop: Stop button in a weather-tight outdoor enclosure to halt operation of the
operator in an emergency situation.
J. Accessory Power: One 24 VAC connection for operator accessories, including a radio receiver
and loop detectors.
K. Equipment: Provide the following optional equipment.
1. Plug-in loop detectors.
2. Thermostat controlled heater.
3. Auxiliary contact blocks.
4. Remote antenna mounting kit.