electric gate operators
section 02829
designed to automatically maintain a suitable temperature inside a control enclosure
down to -40 degrees F (-40 degrees C). Adjustable from 30 degrees to 120 degrees F (0
degrees to 50 degrees C). Used on operators 115V and 575V.
8. Heater: Chamberlain / LiftMaster 6532448 Thermostat Control Heater, Fin Type;
designed to automatically maintain a suitable temperature inside a control enclosure
down to -40 degrees F (-40 degrees C). Adjustable from 30 degrees to 120 degrees F (0
degrees to 50 degrees C). Used on operators 208V - 460V.
9. Pedestals: PED42 Pedestal; 42 inches (1067 mm) high; mounts to pre-existing concrete
pad; 11 gauge steel construction; power coated black; 2 inch x 2 inch (51 mm x 51 mm)
square post; faceplate with universal hole pattern. Includes hardware.
10. Pedestals: PED4272 Dual height Pedestal; 42 and 72 inches high; mounts to pre-
existing concrete pad; 11 gauge steel construction; power coated black; 2 inch x 2 inch
(51 mm x 51 mm) square post; faceplate with universal hole pattern. Includes hardware.
11. Emergency: Chamberlain / LiftMaster ACP17 Fire Access Box.
B. UL Classification:
1. Conforms to Class I, when tested in accordance with UL325.
2. Conforms to Class II, when tested in accordance with UL325.
3. Conforms to Class III, when tested in accordance with UL325.
4. Conforms to Class IV, when tested in accordance with UL325.
C. Operator Enclosure: Weather-resistant, hinged, lockable, 16-gauge steel enclosure over a 10
gauge steel frame.
D. Operator Motor:
1. 1/2 HP Continuous Duty motor with built-in overload protection for gates up to 1200
lbs. (544 kg) and 40 ft. (12 m) overhead or 25 ft. (8 m) cantilever in length.
a. 115 VAC 60 Hz Single Phase operation.
b. 208 VAC 60 Hz Single Phase operation.
c. 230 VAC 60 Hz Single Phase operation.
d. 208 VAC 60 Hz Three Phase operation.
e. 230 VAC 60 Hz Three Phase operation.
f. 460 VAC 60 Hz Three Phase operation.
g. 575 VAC 60 Hz Three Phase operation.
2. 1 HP Continuous Duty motor with built-in overload protection for gates up to 1800 lbs.
(816 kg) and 50 ft. (15 m) overhead or 32 ft. (10 m) cantilever in length.
a. 15 VAC 60 Hz Single Phase operation.
b. 208 VAC 60 Hz Single Phase operation.
c. 230 VAC 60 Hz Single Phase operation.
d. 208 VAC 60 Hz Three Phase operation.
e. 230 VAC 60 Hz Three Phase operation.
f. 460 VAC 60 Hz Three Phase operation.
g. 575 VAC 60 Hz Three Phase operation.
E. Open and Close Limit Settings: Limit switches shall be modular and fully adjustable.
F. Control Circuit: LiftMaster Model GL solid-state digital logic control board including low-