If the gate is not moving in any direction be sure to check all of the LED displays on the
control board. If the board power or charging power LEDs are “ON”, change the
corresponding fuse on the top left corner of the board.
TROUBLESHOOTING
If all electronic sensors fail or are not adjusted properly due to heavy gates, off-track gate,
or obstructed gate path, the breaker will kick-out. Reset the breaker by pressing the reset
button located on the bottom left corner of the control board.
How to Reset the Breaker
How to Check the Fuses
CAUTION
CAUTION
Always disconnect the battery before
resetting the breaker or injury could
occur as the gate starts.
The breaker reset is located at
the bottom left corner of the
control board as shown
Replace fuse with
1.5A - 250V fuse
(Elite Part # Q162)
Robo Fuse