Cut Sheet
By Elite Lighting
Due to the changes of constant improvement in LED technology, all details are
subject to change without notice. Consult factory for up to date information.
www.iuseelite.com
CB2-LED
Architectural LED High Bay
CB2-LED-26000L-DIM10-MVOLT-WD-40K-85 TEST NO.: EL101837
INPUT WATTS: 175.4 LUMENS: 22681 CRI: 85 EFFICACY: 129 CCT: 4000K SPACING CRITERIA: 1.34
Candle Power Distribution (Candelas)
RC - Ceiling Cavity Reflectance RW - Wall Reflectance
ROOM CAVITY RATIO
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
Zonal Lumens Summary
0
Candela Tabulation
Lumens Per Zone
Zone Lumens
0-10 807.60
10-20 2309.48
20-30 3468.8
30-40 4102.32
40-50 4095.01
50-60 3491.81
60-70 2490.4
70-80 1337.26
80-90 349.31
Luminance (Average candela/M
2
)
Angle
in
Degrees
Average
0º
Average
45º
Average
90º
45 13912 13789 13663
55
12788 12571 12366
65
11286 11014 10775
75
9373 9135 9026
85
6716 6585 6714
0 8544.400
5
8583.494
15
8278.176
25
7657.728
35
6710.265
45
5488.541
55
4092.538
65
2661.274
75
1353.552
85
326.563
90
32.544
RC 80% 70% 50% 30% 10% 0%
RW 70% 50% 30% 10% 70% 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 0%
0 119 119 119 119 116 116 116 116 111 111 111 106 106 106 101 101 101 99
1 109 104 100 97 106 102 98 95 98 94 92 94 91 89 90 88 86 84
2 99 91 85 79 97 89 83 78 86 81 76 82 78 74 79 76 73 70
3 91 81 73 66 88 79 72 66 76 70 64 73 68 63 70 66 62 60
4 83 72 63 56 81 70 62 56 68 61 55 65 59 54 63 58 53 51
5 77 64 55 49 75 63 55 48 61 53 48 59 52 47 57 51 47 45
6 71 58 49 43 69 57 49 43 55 48 42 53 47 42 51 46 41 39
7 66 53 44 38 64 52 43 38 50 43 37 49 42 37 47 41 37 35
8 61 48 40 34 60 47 39 34 46 39 33 45 38 33 43 37 33 31
9 57 44 36 30 56 43 36 30 42 35 30 41 35 30 40 34 30 28
10 54 41 33 28 52 40 33 28 39 32 27 38 32 27 37 31 27 25
Zone Lumens %Lamp %Fixt
0-20 3117.08 N.A. 13.70
0-30
6585.88 N.A. 29.00
0-40
10688.19 N.A. 47.10
0-60
18275.02 N.A. 80.60
0-80
22102.68 N.A. 97.40
0-90
22451.99 N.A. 99.00
2153
4306
6459
8612
90º
80º
70º
60º
50º
40º
30º
20º
10º
CB2-LED-18000L-DIM10-MVOLT-WD-40K-85 TEST NO.: EL101838
INPUT WATTS: 133.1 LUMENS: 17267 CRI: 85 EFFICACY: 130 CCT: 4000K SPACING CRITERIA: 1.36
CB2-LED-13000L-DIM10-MVOLT-WD-40K-85
TEST NO.: EL111831
INPUT WATTS: 87.5 LUMENS: 11263 CRI: 85 EFFICACY: 129 CCT: 4000K SPACING CRITERIA: 1.46
Candle Power Distribution (Candelas)
Candle Power Distribution (Candelas)
RC - Ceiling Cavity Reflectance RW - Wall Reflectance
RC - Ceiling Cavity Reflectance RW - Wall Reflectance
ROOM CAVITY RATIO ROOM CAVITY RATIO
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
Zonal Lumens Summary
Zonal Lumens Summary
0
Candela Tabulation
0
Candela Tabulation
Lumens Per Zone
Lumens Per Zone
Zone Lumens
0-10 613.09
10-20 1756.91
20-30 2654.72
30-40 3150.41
40-50 3142.41
50-60 2658.2
60-70 1868.17
70-80 987.39
80-90 253.63
Zone Lumens
0-10 349.67
10-20 1013.75
20-30 1573.52
30-40 1961.46
40-50 2093.29
50-60 1940.99
60-70 1376.76
70-80 703.49
80-90 132.97
Luminance (Average candela/M
2
)
Angle
in
Degrees
Average
0º
Average
45º
Average
90º
45 21230 20845 20527
55
19332 18725 18220
65
16952 16078 15423
75
14002 12877 12136
85
10384 8534 7307
Luminance (Average candela/M
2
)
Angle
in
Degrees
Average
0º
Average
45º
Average
90º
45 21007 21332 20172
55
21078 20782 19972
65
15307 20075 18863
75
14676 13909 16310
85
2722 5630 10509
0 6484.429
5
6536.919
15
6317.216
25
5858.298
35
5140.014
45
4187.965
55
3093.290
65
1998.557
75
1010.959
85
252.472
90
35.578
0 3685.571
5
3700.049
15
3623.681
25
3454.161
35
3224.942
45
2762.633
55
2248.428
65
1203.140
75
706.423
85
44.118
90
14.720
RC 80% 70% 50% 30% 10% 0%
RW 70% 50% 30% 10% 70% 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 0%
0 119 119 119 119 116 116 116 116 111 111 111 106 106 106 101 101 101 99
1 109 104 100 97 106 102 98 95 98 95 92 94 91 89 90 88 86 84
2 99 92 85 79 97 90 84 78 86 81 76 82 78 75 79 76 73 71
3 91 81 73 66 88 79 72 66 76 70 65 73 68 63 70 66 62 60
4 83 72 63 57 81 70 62 56 68 61 55 65 59 54 63 58 54 51
5 77 64 55 49 75 63 55 49 61 54 48 59 52 47 57 51 47 45
6 71 58 49 43 69 57 49 43 55 48 42 53 47 42 52 46 41 39
7 66 53 44 38 64 52 44 38 50 43 37 49 42 37 47 41 37 35
8 61 48 40 34 60 47 39 34 46 39 34 45 38 33 43 37 33 31
9 57 44 36 31 56 44 36 30 42 35 30 41 35 30 40 34 30 28
10 54 41 33 28 52 40 33 28 39 32 28 38 32 27 37 31 27 25
RC 80% 70% 50% 30% 10% 0%
RW 70% 50% 30% 10% 70% 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 0%
0 119 119 119 119 116 116 116 116 111 111 111 106 106 106 101 101 101 99
1 109 104 100 96 106 102 98 94 97 94 91 93 91 88 89 87 86 83
2 99 91 84 78 96 89 82 77 85 80 75 82 77 73 78 75 72 69
3 90 79 71 65 87 78 70 64 75 68 63 72 66 62 69 64 60 58
4 82 70 61 55 80 69 61 54 66 59 53 64 58 53 61 56 52 50
5 76 63 54 47 73 61 53 47 59 52 46 57 51 45 55 49 45 43
6 70 56 47 41 68 55 47 41 53 46 40 52 45 40 50 44 39 37
7 64 51 42 36 63 50 42 36 48 41 35 47 40 35 45 39 35 33
8 60 46 38 32 58 46 37 32 44 37 31 43 36 31 42 35 31 29
9 56 42 34 29 54 42 34 28 41 33 28 39 33 28 38 32 28 26
10 52 39 31 26 51 39 31 26 37 30 26 36 30 25 35 30 25 23
Zone Lumens %Lamp %Fixt
0-20 2370.00 N.A. 13.70
0-30
5024.72 N.A. 29.10
0-40
8175.13 N.A. 47.30
0-60
13975.74 N.A. 80.90
0-80
16831.28 N.A. 97.50
0-90
17084.92 N.A. 98.90
Zone Lumens %Lamp %Fixt
0-20 1363.42 N.A. 12.10
0-30
2936.94 N.A. 26.10
0-40
4898.4 N.A. 43.50
0-60
8932.68 N.A. 79.30
0-80
11012.93 N.A. 97.80
0-90
11145.9 N.A. 99.00
1639
3278
4918
6557
927
1853
2780
3706
90º
80º
70º
60º
50º
40º
30º
20º
10º
90º
80º
70º
60º
50º
40º
30º
20º
10º
Cone of Light
BEAM DIA. MEASURED AT 50% OF NADIR F.C.
Distance to
Plane
Initial
Footcandle
at Nadir
Beam
diameter
4.0 22.4 fc 44.9 ft
8.0 5.61 fc 89.7 ft
12.0 2.49 fc 134.6 ft
16.0 1.4 fc 179.5 ft
20.0 0.9 fc 224.3 ft
24.0 0.62 fc 269.2 ft
Cone of Light
BEAM DIA. MEASURED AT 50% OF NADIR F.C.
Distance to
Plane
Initial
Footcandle
at Nadir
Beam
diameter
4.0 12.8 fc 58.1 ft
8.0 3.19 fc 116.1 ft
12.0 1.42 fc 174.2 ft
16.0 0.8 fc 232.2 ft
20.0 0.51 fc 290.3 ft
24.0 0.35 fc 348.3 ft
Cone of Light
BEAM DIA. MEASURED AT 50% OF NADIR F.C.
Distance to
Plane
Initial
Footcandle
at Nadir
Beam
diameter
4.0 29.6 fc 45.4 ft
8.0 7.39 fc 90.7 ft
12.0 3.29 fc 136.1 ft
16.0 1.85 fc 181.5 ft
20.0 1.18 fc 226.9 ft
24.0 0.82 fc 272.2 ft