315 MHZ RADIO RECEIVER PROGRAMMING
Setting Output Duration (M) or (C):
P2
Changing output duration from
Momentary to Constant.
The receiver is factory set at (M) Momentary. To verify, refer to the label next to jumper P2. (See illustration below)
For commercial applications, the receiver can be set to either (C) constant or (M) momentary closure.
With the jumper in the (M) momentary position, the contacts will close for 1/4 second regardless of the length of remote control
transmission.
With the jumper in (C) constant position, the contacts will stay closed as long as the remote control continues transmitting. Push and
HOLD remote button to open or close gate.
To reduce the risk of SERIOUS INJURY
or DEATH from a moving gate:
• ALWAYS keep remote controls out of
reach of children. NEVER permit
children to operate, or play with
remote control.
• Activate gate ONLY when it can be
seen clearly, is properly adjusted, and
there are no obstructions in gate’s
path.
• ALWAYS keep gate in sight until
completely closed. NEVER permit
anyone to cross path of a moving
gate.
To AVOID damaging receiver, disconnect
receiver’s power before changing jumper.
To reduce the risk of SERIOUS INJURY or DEATH, the use of
CONSTANT OPERATION on residential operators is
PROHIBITED.
Programming Radio Receiver:
1. Press and release the “Learn” button on the receiver. The learn indicator light will
glow steadily for 30 seconds.
2. Within 30 seconds, press and hold the button on the hand-held remote. The operator
will now operate when the push button on the remote control is pressed.
Repeat Steps 1 and 2 for each remote control that will be used.
Erase ALL Remote Control Codes:
Press and hold the “Learn” button on the receiver panel until the indicator light turns
off (about 6 seconds). All previous codes are now erased. Reprogram each remote you
wish to use.