Owner`s manual
28
ADJUSTING REVERSE SENSOR
POSITIVE STOP SETTING
This switch is to be turned to YES when a Physical Stop is used to stop the gate(s). This can allow the gate(s) to be locked or secured
in the closed position. The operator will use the “Positive Stop” at the gate’s closed position. It is still necessary to adjust the operator’s
limit switches at the closed position. The control board will look for the limit close first, then the positive stop.
NOTE: Mount the positive stop on concrete
ONLY and secure with concrete anchors.
Adjust the reverse sensor so when the gate hits any object while opening, it will STOP, and when the gate hits any object while closing,
it will REVERSE. The reverse sensor must be adjusted while the gate is opening or closing.
Part # APSA
Positive stop works the same on the single or
master/second control board.
Reverse sensor works the same on the single or
master/second control board.
Sensor is too sensitive = if the gate stops in midcycle or reverses by itself.
Sensor is not sensitive enough = if the gate hits an object and does not stop or reverse.
Maximum Sensitivity
Minimum Sensitivity