Owner`s manual
Second ONLY
RED
BRAKE
BROWN
BLUE
LIMITS
GREEN
CENTER
LOOP
BURGLAR
ALARM
INPUT
UL SENSOR
9101112 13 14 15 16 17 18
21
UL ALARM CONNECTION
BURGLAR ALARM CONNECTIONS
This UL alarm is required for UL-325. It will go off after 2 consecutive events on the reverse sensor or UL sensor occur.
The UL alarm will sound for a period of 5 minutes unless the Stop/Reset button is pressed or a new command is received by the Strike
Input Connection. The reset button will shut off an activated audio alarm and reset the operator to function again. See page 32.
Mount alarm on bottom of control box
to protect it from the weather.
The control board provides a relay with a normally open contact to
interface with a house alarm.
When interfacing with a house burglar alarm you must install
positive stops at the gate closed position. See page 28.
Connect the alarm plug
to the J4 “Alarm”
connection on the
control board. See
page 15.
Connect the alarm plug
to the J4 “Alarm”
connection on the
control board.
See page 15.
If the audio alarm goes off, always check the gate area for:
• Obstructions in the gate path.
• Damage to the gate and/or gate operator.
House Alarm
(Normally Open) If the gate is forced open without a valid
command, the proximity switch will be activated, causing
the house alarm to activate.
Proximity Switch
Control Board Relay
Contact Rating
0.5 Amp - 125 Vac
1 Amp - 24 Vdc
Part # APRS
Surge Suppressor