The Chamberlain Group, Inc. 845 Larch Avenue Elmhurst, Illinois 60126-1196 www.liftmaster.com MIRACL E - ONE ™ VEHICULAR ACTUATOR GATE OPERATOR OWNER’S MANUAL THE MIRACLE-ONE™ IS FOR USE ON VEHICULAR PASSAGE GATES ONLY AND NOT INTENDED FOR USE ON PEDESTRIAN PASSAGE GATES.
TABLE OF CONTENTS SPECIFICATIONS AND WARNINGS WARNING Carton Inventory and . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Model Classification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Safety Installation Information . . . . . . . . . . . . . . . . . . . . . . . . . . Suggested Entrapment Protection Device Locations . . . . . . . . . Safety Precautions . . . . . . . . .
CARTON INVENTORY Arm (Sold Individually) 2 Keys Back Steel Mounting Bracket Front Steel Mounting Bracket Flexible Conduit with Attachment Fitting Operator Arm Single Controller Accessory Kit 34 Vdc 1.7 A Transformer Battery Manual UL Alarm Control Box Assembly (Single) Warranty Card 2 Warning Placards Master/Second Controller Accessory Kit 40 ft Shielded Cable Junction Box with Cover Terminal Connector 34 Vdc 1.
SPECIFICATIONS Mechanical Specifications Motor – Cycles – Shipping Weight: Torque – Finishing – Capabilities – Operator Travel Speed – 24 Vdc, 12 Amps. 100 / Day. (Consult factory for solar applications) Single Unit: 58 lbs. – Master/Second: 89 lbs. 600 lbs. of torque. Aluminum. Maximum gate size 15' wide, 600 lbs. 14 to 18 seconds 90 opening. Top 3.5" 39.5" Front Back 4" 5.75" Side Electrical Specifications Running System – Modular Board – Sensor – Top 5.25" 10.5" 12.
UL325 MODEL CLASSIFICATIONS The Miracle-One™ is intended for use in Class I - III vehicular swing gate applications: Class I – Residential vehicular gate operator A vehicular gate operator (or system) intended for use in a home of one-to four single family dwellings, or a garage or parking area associated therewith.
SAFETY INSTALLATION INFORMATION 1. Vehicular gate systems provide convenience and security. Gate systems are comprised of many component parts. The gate operator is only one component. Each gate system is specifically designed for an individual application. 2. Gate operating system designers, installers and users must take into account the possible hazards associated with each individual application. Improperly designed, installed or maintained systems can create risks for the user as well as the bystander.
SUGGESTED ENTRAPMENT PROTECTION DEVICE LOCATIONS WARNING To prevent SERIOUS INJURY or DEATH from a moving gate: • Entrapment protection devices MUST be installed to protect anyone who may come near a moving gate. • Locate entrapment protection devices to protect in BOTH the open and close gate cycles. • Locate entrapment protection devices to protect between moving gate and RIGID objects, such as posts or walls. • A swinging gate shall NOT open into public access ways.
SAFETY PRECAUTIONS The Miracle-One™ is for use on Vehicular Passage Gates ONLY and NOT INTENDED for use on Pedestrian Passage Gates. WARNING To prevent SERIOUS INJURY or DEATH from a moving gate: • Entrapment protection devices MUST be installed to protect anyone who may come near a moving gate. • Locate entrapment protection devices to protect in BOTH the open and close gate cycles. • Locate entrapment protection devices to protect between moving gate and RIGID objects, such as posts.
Installation INSTALLATION SETUPS Single Operator Maximum gate length 15 ft. Maximum gate weight is 600 lbs. Warning Placard on both sides of gate. Control Box 40-50399A UL Alarm Radio Receiver Antenna Water Tight Conduit (Not provided) Earth Ground Rod is highly recommended. See page 18. NOTE: Weld a horizontal bar across entire gate on any installation for strength. Master/Second Operators Maximum gate length 15 ft. for each gate. Maximum gate weight is 600 lbs. for each gate.
MOUNTING OPERATOR THAT OPENS TO THE OUTSIDE NOTE: Weld Re-Bar Behind Gate Hinges for Maximum Strength. Gate Hinge Gate Hinge Heavy Steel Plate for Reinforcement (Not provided) Steel Re-Bar Heavy Steel Plate for Reinforcement (Not provided) Back Steel Bracket (Reinforce if necessary) Top View Back Steel Bracket (Reinforce if necessary) Heavy Steel Plate Gate Hinge Gate Hinge Typical Steel Post Setup Indexing on mounting hole in the front steel bracket.
MOUNTING OPERATOR THAT OPENS TO THE INSIDE NOTE: Weld Re-Bar Behind Gate Hinges for Maximum Strength. Gate Hinge Gate Hinge Steel Re-Bar Heavy Steel Bracket (Reinforce if necessary) Heavy Steel Plates for Reinforcement (Not provided) 10" Minimum Back Steel Plates for Reinforcement (Not provided) Top View Back Steel Bracket (Reinforce if necessary) Heavy Steel Plate Gate Hinge Gate Hinge Typical Masonry Column Setup 8.5" Typical Steel Post Setup 25.
MOUNTING OPERATOR Unscrew 4 screws on top of operator to remove cover. Release the mechanical lock by turning the key to the horizontal position. If using a gate crossbar, weld bar across all pickets. Do not weld the crossbar on just a few pickets, or they could bend. The Miracle-One™ can be mounted on top of the gate frame. NOTE: See page 7 for mounting limitations. Make sure that the operator is mounted level or it will not function properly.
MOUNTING OPERATOR (CONTINUED) Bolt NOTE: Front and back bracket hardware must be installed as shown. Nuts must be tight or operator will not work correctly. Bushing Traveler Carriage Back Bracket Washer on top of bracket. Nut Front Bracket Nut Position the Miracle-One™ horizontally level on the closed gate, where desired. For strength purposes, the front steel bracket must be attached in an area that can withstand heavy forces. Additional reinforcement steel plates may be necessary for mounting. 2.
MOUNTING OPERATOR (CONTINUED) After permanently mounting operator back on brackets, lock the operator by turning the key to the vertical position while pushing or pulling on the gate until you hear the key release click into place. The gate should not move after the operator has been locked.
CONNECTING OPERATOR(S) TO CONTROL BOX NOTE: Reinstall all components back into control box when finished connecting operator(s) to control box. See previous page. Single Operator CAUTION To AVOID damaging operator: DO NOT over-bend the cord from the operator. Doing this will cause the wires to eventually break. Flexible conduit’s attachment assembly. Master/Second Operators Master Second NOTE: All connections need to be waterproof.
CONTROL BOARDS DESCRIPTIONS Master/Second Single CAUTION To AVOID damaging the control board, replace fuses ONLY with same type and rating specified below. 1. Open or Close Relay LED 16. Charge OK LED 2. Control Relay LED 17. Power LED 3. Motor Fuse (8 Amp Single) (15 Amp Master/Second) 18. Timer Active LED 4. J1 Battery, Surge Suppressor and Reset Button Connection 19. Timer Adjustment (3 to 60 sec.) See page 26. 5. Strike Open LED 20. Switch - Timer, Off / On. See page 26. 6.
SURGE SUPPRESSOR CONNECTIONS BLACK WHITE RED 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Removable Terminal Connectors 1 7 2 3 10 5 Miracle-One™ Single 11 6 12 Ground NOTE: You MUST use Shielded Wire for the blue and green lines. Shield must be grounded. 1 Black 2 White 3 Red 4 Shielded Brown 5 Blue 6 Green Refer to Page 19 Miracle-One™ Second Miracle-One™ Master 1 Black 2 White NOTE: You MUST use Shielded Wire for the blue and green lines. Shield must be grounded.
SURGE SUPPRESSOR CONNECTIONS Green Ground Wire Refer to Page 18 Refer to Page 20 Refer to Page 20 Solar Power 34 Vdc 1.7 A Transformer Polarity does not matter Refer to Page 29 24 Vdc Factory Installed Radio Receiver Board +24 Volt Red Ground Black Radio White Refer to Page 22 Works as “3 Push Button” Control N.O. Remote NOT Included Com 24 Vdc Photo Electric Sensors Part # CPSN4 Refer to Page 24 Push Button Key Switch Card Reader Digital Lock Brown Wires Blue Wires N.O.
Wiring WARNING To reduce the risk of SEVERE INJURY or DEATH: • ANY maintenance to the operator or in the area near the operator MUST NOT be performed until disconnecting the electrical power and locking-out the power via the operator power switch. Upon completion of maintenance the area MUST be cleared and secured, at that time the unit may be returned to service. • Disconnect battery and 34 Vdc transformer or solar panel BEFORE proceeding.
WIRING OPERATOR(S) TO CONTROL BOARD Single Controller WARNING CAUTION To prevent SERIOUS INJURY or DEATH from a moving gate: DO NOT connect the battery at this time. To ENSURE proper operation of external devices: • ENSURE bare wires make good contact inside removable terminal connections. • DO NOT let wire insulation interfere with connection. Master/Second Controller Water tight conduit not provided from the second operator.
DC POWER CONNECTION NOTE: Master/second control board shown to demonstrate proper conduit arrangement. The same connection sequence applies to the single control board. Plug in the transformer and connect the battery plug into the surge suppressor J1 battery plug. The “Timer” LED will flash “3 times”. After that, check the “Charge OK” LED...... ......it must be “ON”. If the board or charging LEDs are lit, replace the fuses ONLY with type and sizes specified. See page 35.
UL ALARM CONNECTION This UL alarm is required for UL-325. It will go off after 2 consecutive events on the reverse sensor or UL sensor occur. The UL alarm will sound for a period of 5 minutes unless the Stop/Reset button is pressed or a new command is received by the Strike Input Connection. The reset button will shut off an activated audio alarm and reset the operator to function again. See page 32. If the audio alarm goes off, always check the gate area for: • Obstructions in the gate path.
WIRING ADDITIONAL INPUTS Strike Input #21 and #22 Wiring at #21 and #22 will be recognized as an Open Only command, and Will Not close the gate. To automatically Close the gate after an open cycle, the control board timer must be turned ON. See page 26 about timer control. Works as “Open Only” command. Separate Power for Device Separate Power for Device Input #23 and #24 To provide a Close command use #23 and #24. Wiring at #23 and #24 will be recognized as a Three Push Button command.
24 VDC EXTERNAL LOOP DETECTOR WIRING NOTE: Refer to the loop detector manual for more specific information. Part # A24 (Sold Individually) 24 Vdc “Center” Loop Detector - Allows gate to stay open when vehicles are obstructing path. Caution: This option is for all vehicles including ones less than 14' long. Center loop system requires two safety loops. Center 24 Vdc “Safety” Loop Detector - Allows gate to stay open when vehicles are obstructing path. Caution: Suggested for vehicles 14 feet or longer.
ENTRAPMENT PROTECTION DEVICE Non-Contact Sensors (24 Vdc Photo Electric Sensors) To reduce the risk of injury, install photo electric sensors when the gate opens to less than 18” from a wall or any other object or potential entrapment installation.
MAGLOCK OR SOLENOID CONNECTION NOTE: ONLY the optional relay module will allow interface with the maglock or solenoid. The gate opening direction must be previously set, see page 26. Pin 1 is used when control board is set to Open Inside. Pin 3 is used when control board is set to Open Outside. The relay connection is the same on the master/second control board. CAUTION To ENSURE proper operation of external devices: • ENSURE bare wires make good contact inside removable terminal connector.
Adjustments CAUTION To reduce the risk of SERIOUS INJURY or DEATH: Disconnect power BEFORE performing ANY adjustments. SET GATE OPENING DIRECTION Inside Property Gate Opens Outward Gate Opens Inward Inside Property The opening direction works the same on the single or master/second control board. SETTING TIMER The timer works the same on the single or master/second control board. To use the automatic close for the gate system, the timer should be switched to the “ON” position.
LIMIT SWITCH ADJUSTMENTS Remove operator cover and unlock the operator to adjust the gate’s traveling distance with the limit switches. Loosen the 2 screws of each limit switch armature. Position the second limit switches of each armature to stop the gate in the “full open” and “full closed” positions (See illustration below). Re-tighten armature screws when gate positions are correct. Replace operator cover with 4 screws when finished adjusting switches.
ADJUSTING REVERSE SENSOR Adjust the reverse sensor so when the gate hits any object while opening, it will STOP, and when the gate hits any object while closing, it will REVERSE. The reverse sensor must be adjusted while the gate is opening or closing. Sensor is too sensitive = if the gate stops in midcycle or reverses by itself. Sensor is not sensitive enough = if the gate hits an object and does not stop or reverse. Reverse sensor works the same on the single or master/second control board.
5 MHZ RADIO RECEIVER PROGRAMMING Setting Output Duration (M) or (C): The receiver is factory set at (M) Momentary. To verify, refer to the label next to jumper P2. (See illustration below) For commercial applications, the receiver can be set to either (C) constant or (M) momentary closure. With the jumper in the (M) momentary position, the contacts will close for 1/4 second regardless of the length of remote control transmission.
CLOSE DELAY FOR OVERLAPPING GATES Master/Second Gates with Overlap Overlap positioned on the Outside. Inside Property Inside Property Overlap positioned on the Inside. Gate’s Open Inside When “Close Delay” is turned ON, the Master operator will delay closing it’s gate to compensate for the gate overlap. It works for any opening direction and overlap position. Gate’s Open Outside Master/second control board Overlap positioned on the Outside. Inside Property Overlap positioned on the Inside.
Maintenance and Operation IMPORTANT SAFETY INSTRUCTIONS WARNING To reduce the risk of SEVERE INJURY or DEATH: 1. READ AND FOLLOW ALL INSTRUCTIONS. 2. NEVER let children operate or play with gate controls. Keep the remote control away from children. 3. ALWAYS keep people and objects away from the gate. NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE. 4. Test the gate operator monthly. The gate MUST reverse on contact with a rigid object or stop when an object activates the non-contact sensors.
BUILT-IN RESET BUTTON When the gate operator’s audio alarm (See below) has been tripped, the reset button must be pushed for the operator to function again. The reset button will shut off an activated audio alarm and reset the operator to function again. UL Alarm If the audio alarm goes off, always check the gate area for: • Obstructions in the gate path. • Damage to the gate and/or gate operator.
EMERGENCY MANUAL RELEASE Step 1: To move the gate during an emergency or power failure, insert key and turn counterclockwise to Unlock the operator from the gate. Key provided Step 2: Move the gate manually to the full open position 90°. Full Open Position Step 3: Re-Lock the operator by turning the key clockwise while pushing or pulling on the gate until you hear the key release click into place. The operator can resume normal operation as soon as power is restored.
Troubleshooting The Gate Will Not Operate with Remote: The radio receiver LED on the control board remains “ON” when using the remote control. Probable Causes: 1. Stuck remote control button. 2. The radio receiver has malfunctioned in the “ON” position. Solutions: Unstick remote control button. Cycle the power to the radio receiver. The Gate Will Not Operate with Remote: The radio receiver LED on the control board remains “OFF” when using the remote control. Solutions: Get new remote control battery.
TROUBLESHOOTING CONTINUED Check the Fuses If the gate is not moving in any direction be sure to check all of the LED displays on the control board. If the board power or charging power LEDs are on, change the corresponding fuse on the right side of the board. Master/Second Board If the motor will not work, and all LED's on the board are ok, check the fuse on the left side of the board and replace if necessary.
WIRING DIAGRAM • MIRACLE-ONE™ SINGLE MIRACLE SURGE PROTECTION ® LAKE FOREST, CALIFORNIA www.eliteaccess.
WIRING DIAGRAM TABLE • MIRACLE-ONE™ SINGLE Miracle-One™ Single Control Board J# J Pin # Signal Type J1 J1 J1 J1 J1 J1 J1 J1 J1 J1 J2 J2 J2 J3 J3 J3 J3 J3 J3 J3 J3 J3 J3 J3 J3 J3 J3 J3 J3 J4 J4 J4 J4 1 2 3 4 5 6 7 8 9 10 1 2 3 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 Reset Button - Red Reset Button - Black Limits - Green Limits - Blue Brake - Brown Brake - Red Motor - White Motor - Black Battery + (Red) Battery – (Black) Close + 12 V Open 24 Vac Power 24 Vac Power Power (Radio) Radio Ground (Radio
WIRING DIAGRAM • MIRACLE-ONE™ MASTER/SECOND NOTE: See table on next page.
WIRING DIAGRAM TABLE • MIRACLE-ONE™ MASTER/SECOND Miracle-One™ Master/Second Control Board J# J Pin # Signal Type Direction J1 J1 J1 J1 J1 J1 J1 J1 J1 J1 J1 J1 J1 J1 J1 J1 J2 J2 J2 J3 J3 J3 J3 J3 J3 J3 J3 J3 J3 J3 J3 J3 J3 J3 J3 J4 J4 J4 J4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 Reset Button - Red Reset Button - Black Limits - Green Second Limits - Blue Second Brake - Brown Second Brake - Red Second Motor - White Second Motor - Black Second Limits -
Repair Parts REPAIR PART ILLUSTRATIONS 3 28 7 4 2 10 18 29 26 2 16 19 SIN GLE LIM Y ITS 20 MOT SEC OR OND LIM ITS 15 16 17 18 SAFETY LOOP 14 19 20 STRIKE OPEN 12 13 21 22 GROUND 12 23 RADIO 11 24 +24 VOLT 10 25 +24 VAC INPUT RED BROWN BRA ONL KE Y 9 BLUE 8 GREEN 7 BURGLAR ALARM INPUT 6 UL SENSOR 5 CENTER LOOP RED BROWN 4 BLUE 3 GREEN BLACK MA BRA STE KE R ONL BLACK 2 WHITE 1 WHITE MOT OR OR 6 26 27 SIN GLE MOT SEC OR OND BRA ONL KE Y LIMI T
REPAIR PART NAMES AND NUMBERS INDIVIDUAL PARTS ITEM PART# 2 3 4 5 6 7 8 9 10 11 12 13 14 16 17 18 19 20 21 22 23 24 25 26 27 28 29 NOT SHOWN DESCRIPTION ITEM PART# Q162 Q222 Q223 Q310 Q311 1.
Accessories Outdoor Siren with Strobe Light Part # ASSA Power Hinges For more information about accessories: www.liftmaster.
HOW TO ORDER REPAIR PARTS OUR LARGE SERVICE ORGANIZATION SPANS AMERICA. INSTALLATION AND SERVICE INFORMATION IS AS NEAR AS YOUR TELEPHONE . SIMPLY DIAL OUR TOLL FREE NUMBER: 1-800-528-2806 www.liftmaster.com WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION: • PART NUMBER • PART NAME • MODEL NUMBER Address orders to: THE CHAMBERLAIN GROUP, INC. Technical Support Group 6050 S. Country Club Road Tucson, Arizona 85706 Warranty Policy THREE YEAR LIMITED WARRANTY The Chamberlain Group, Inc.
Installation Checklist 1. Owner and Installer must read all warnings and safety precautions. (Pages 4-7) 2. Make sure control box is securely mounted. (Page 13) 3. Operator arm must be securely and correctly fastened to mounting brackets. (Page 12) 4. Operator arm must be level in both directions. (Page 11) 5. When gate is pulled, No slippage of operator arm should occur. (Page 13) 6. Control box should be grounded to an earth ground rod within 3 feet. (Page 18) 7.