Specifications

8
MAGLOCK ALARM
MADE IN USA
OPEN
INSIDE
STOP BY
POSITIVE
STOP
NO YES
OPEN
OUTSIDE
REVERSE
SENSOR
ALARM
SENSOR
ON
TIMER
POWER
REPLACE FUSE
WHEN LED IS ON
CHARGE OK
BAT LOW
CENTRAL
STRIKE
OPEN
SAFETY
LOOP
CENTER
LOOP
RADIO
REC
CONTROL
60 3
OFF
SYSTEM
ON
8A 125V
WARNING: FOR CONTINUED PROTECTION
AGAINST FIRE REPLACE ONLY WITH
SAME TYPE & VOLTAGE FUSE
2A 250V
1.5A 250V
WARNING: FOR CONTINUED
PROTECTION AGAINST FIRE
REPLACE ONLY WITH SAME
TYPE & VOLTAGE FUSE
ACCESS SYSTEMS INCACCE SS SY STE MS INC
PHOTOCELL INSTALLATION
12
3456
24V to
240VDC
(NO1)
Black 22 AWG
Black 16 AWG
Black 16 AWG
Red 22 AWG
To reduce the risk of injury, You must install a photocell sensor when the gate opens to less than 18”
from a wall or any other object or potential entrapment installation. Follow the installation instructions
provided with the photocell sensor for accurate placement of the photocell and the reflector.
Elite Part # A OMRON
If multiple sensors are being used, all of the photo beam sensors
are to be connected in parallel at the sensor input on the control
board.
If you are going to use a non-contact sensor as a secondary
entrapment protection you should use a recognized component to
component to comply with the revised UL 325 intended to be used
in class I or class II gate operator, like the following: OMRON
Retro-Reflective Photocell, Model: E3K-R10K4-NR
(C1)
LIGHT ONLIGHT ON
DARK ON
This switch must be in the
"Light On" position or
photocell will not function
correctly.
J3 Plug
Potential Entrapment
Area (Shaded)
Gate in Open Position
Gate in Closed Position
Photocell
Less than 18"
Reflector
and
Bracket
20
1
6
1
5
1
4
1
3
1
1
9
8
6
2
1
1212
7
4
5
3
1010
J3 Plug
Connector
Important!