Specifications
SAFETY AND CENTER LOOP INSTALLATION
Fill Loop Cuts
with Proper Sealer
Center Loop Even
with Open End
of Gate
7'
4'
4'
4'
4'
4'
4'
4'
15'
Use 14 AWG "uf" Grade
Stranded Wire
To Loop
Detector
Loop
Cut
1/4"
Wide
Three
Wire
Layers
1 1/2"
1/4"
J3 Plug
Connector
Twisted
Wires
From Loop
Cuts
1
6
1
5
1
4
1
3
1
1
1
0
9
3
2
1
1212
7
5
4
8
6
Center Loop
YELLOWBLUE
BLUE YELLOW
Safety Loop
OUT
IN
Safety
Loop
Safet
y
Loop
Center
L
oop
19
4'
Be sure to twist
wires together.
Important:
If the gate is closing and receives a safety loop command, the gate WILL NOT reopen.
It will stop and resume closing, once the car clears the loop.
Important:
Loop Cut