T A B L E O F C O N T E N T S Attention: This handbook is exclusively for qualified installation personal, and assistance and/or maintenance service. - The performances indicated in this handbook are valid only if a correct assembly has been carried out.
U L L I S T I N G S A N D I N S T R U C T I O N S Installation Instructions Regarding the Gate Operator A) Install the gate operator only when: 1. The operator is appropriate for the construction and the usage Class of the gate. 2. All openings of a horizontal slide gate are guarded or screened from the bottom of the gate to a minimum of 4 feet (1.2 m) above the ground to prevent a 2 1/4inch (57.
U L L I S T I N G S A N D I N S T R U C T I O N S G) For a gate operator utilizing a non-contact sensor such as a photo beam: 1. See instructions on the placement of non-contact sensor for each Type of application. 2. Care shall be exercised to reduce the risk of nuisance tripping, such as when a vehicle trips the sensor while the gate still moving. 3.
U L L I S T I N G S A N D I N S T R U C T I O N S Important Safety Instructions Warning - To reduce the risk of injury or death: 1. READ AND FOLLOW ALL INSTRUCTIONS. 2. Never let children operate or play with gate controls. Keep the remote control away from children. 3. Always keep people and objects away from the gate while the gate is in operation. NO ONE SHOULD CROSS THE PATH OF A MOVING GATE! 4. Test the gate operator monthly.
U L L I S T I N G S A N D I N S T R U C T I O N S Gate – A moving barrier such as a swinging, sliding, raising lowering, rolling, or like, barrier, that is a stand-alone passage barrier or is that portion of a wall or fence system that controls entrance and/or egress by persons or vehicles and completes the perimeter of a defined area.
W A R N I N G S A N D P R E C A U T I O N S Warning - To reduce the risk of injury to persons, The Miracle-1 is for Vehicular Gate use ONLY! Be sure to read and follow all these important instructions before installation of the gate operator. Elite Access Systems, Inc. is not responsible for improper installation or failure to comply with local building and electrical codes. DO NOT install upside down. DO NOT install on a few pickets, they will bend. Weld a reinforcement bar across entire gate.
P R O C E D U R E O p e n F O R T o I N S T A L L A T I O N T h e I n s i d e Important: Weld Re-Bar Behind Gate Hinges for Maximum Strength Gate Hinge Gate Hinge Steel Re-Bar Heavy Steel Plates for Reinforcement (Not Supplied) 10" Minimum Back Steel Bracket (Reinforce if necessary) Heavy Steel Plates for Reinforcement (Not Supplied) Back Steel Bracket (Reinforce if necessary) Heavy Steel Top View Plate Post Setup Gate Hinge Typical Masonry Column Setup Typical Steel Post Setup 25.75" 8.
P R O C E D U R E O p e n F O R T o T h e I N S T A L L A T I O N O u t s i d e Important: Weld Re-Bar Behind Gate Hinges for Maximum Strength Gate Hinge Gate Hinge Heavy Steel Plate for Reinforcement (Not Supplied) Steel Re-Bar Heavy Steel Plates for Reinforcement (Not Supplied) Back Steel Bracket (Reinforce if necessary) Back Steel Bracket (Reinforce if necessary) Gate Hinge Typical Masonry Column Setup Typical Steel Post Setup Indexing on mounting hole in the front steel bracket.
P R O C E D U R E F O R M o u n t i n g I N S T A L L A T I O N I n s t r u c t i o n s Step 1: Remove the 4 screws and lift the operator cover off. Step 2: Release the mechanical lock by turning the key to the horizontal position. Step 3: Position the Miracle 1 horizontally level on the closed gate, where desired. For strength purposes, the front steel bracket must be attached in an area that can withstand heavy forces. Additional reinforcement steel plates may be necessary for mounting.
P R O C E D U R E F O R M o u n t i n g I N S T A L L A T I O N I n s t r u c t i o n s Step 4 (con't): The gate must be in the closed position. Make sure the operator is kept level while tack welding the front and back steel brackets and reinforcement steel plates in position. After all tack welding is finished, remove the operator! Refer to Step 6 2.25" Vertical Height Difference Refer to Step 7 Step 5: With the operator removed, completely weld around the brackets and plates on the gate.
P R O C E D U R E F O R M o u n t i n g I N S T A L L A T I O N I n s t r u c t i o n s Step 8: Make sure that the operator is level or it will not function properly. An off-level installation may cause the gate or operator to fail prematurely. Step 9: Lock the operator by turning the key to the vertical position while pushing or pulling on the gate until you hear the key release click into place. the gate should not move after the operator has been locked.
P R O C E D U R E A d j u s t i n g F O R t h e I N S T A L L A T I O N L i m i t S w i t c h e s Step 11: Adjust the travel distance of the gate with the limit switches. Loosen the 2 bolts of each limit switch armature. Slide to adjust. Position the outside limit switches of each armature to stop the gate in the “full open” and “full closed” positions. Re-tighten armature bolts when gate positions are correct.
R E M O V I N G T H E C O N T R O L B O A R D Unscrew the 4 Phillips head screws from the plastic cover and remove. MAGLOCK ALARM SYSTEM ON REVERSE SENSOR MAGLOCK ALARM SENSOR ALARM SENSOR POWER CHARGE OK BAT CENTRAL LOW CONTROL 2A 250V TIMER OFF 3 OPEN OUTSIDE OPEN INSIDE 1.
WIRING 1 OPERATOR TO CONTROL BOARD Caution: Do Not over-bend the cord from the operator. Doing this will cause the wires to eventually break. Wire Gauge: 16 AWG / 200 Ft.
W I R I N G 2 O P E R AT O R S Field Wiring Box M A S T E R / S L AV E 6 Wires from Operator in Conduit Wire Gauge: 16 AWG / 200 Ft. Operator 1 (Master) Operator 2 (Slave) Caution: Do Not over-bend the cord from the operator. Doing this will cause the wires to eventually break.
C H O O S I N G G AT E M O V E M E N T D I R E C T I O N Switch the “Open Inside / Open Outside” switch on the control board to the corresponding position for the proper direction. MAGLOCK ALARM SYSTEM ON REVERSE SENSOR ALARM SENSOR OPEN OUTSIDE REPLACE FUSE WHEN LED IS ON YES 60 OFF 3 POWER CHARGE OK BAT CENTRAL LOW CONTROL 2A 250V ON 1.
C O N N E C T I N G P O W E R S U P P L Y Connect the two yellow wires from the J3 plug connector to low voltage, direct burial landscape lighting cable, 14 gauge/300 watt not exceeding 500 ft, 10 AWG up to 1000 ft. Connect the lighting cables into Elite's plug-in transformer 24 VAC (Included). Polarity does not matter. The transformer needs 115 VAC.
W I R I N G A D D I T I O N A L I N P U T S Important: Wiring at 7 and 12 will be recognized as an Open Only command, and Will Not close the gate. To Close the gate with this wiring configuration, the control board timer must be turned ON. If the timer is not turned on, the gate will remain open. To provide close command use 4 and 5. Wiring at 4 and 5 will be recognized as a Three Push Button command. The First command will open the gate. The Second command will stop the gate.
SAFETY AND CENTER LOOP INSTALLATION OUT 15' 4' 4' Safe Loop ty 4' 4' Cen Loo ter p Center Loop Even with Open End of Gate 4' 4' Twisted Wires 4' Safe Loo ty p 4' 7' IN From Loop Cuts Center Loop BLUE 1 1/2" Fill Loop Cuts with Proper Sealer YELLOW J3 Plug Connector 16 15 14 13 12 11 10 9 BLUE 1/4" Use 14 AWG "uf" Grade Stranded Wire 8 7 6 5 4 3 2 1 YELLOW Safety Loop Important: Be sure to twist wires together.
P H O T O C E L L I N S T A L L A T I O N Gate in Closed Position To reduce the risk of injury, You must install a photocell sensor when the gate opens to less than 18” from a wall or any other object or potential entrapment installation. Follow the installation instructions provided with the photocell sensor for accurate placement of the photocell and the reflector.
C O N T R O L 28 B O A R D 27 D E S C R I P T I O N 26 25 24 23 22 21 20 19 18 1 17 2 16 15 14 1 13 12 11 8 10 9 3 4 5 6 7 8 1 Open or Close Relay LED 15 Board Fuse 2 Control Relay LED 16 Replace Charging Power Fuse LED 3 Motor Fuse 17 Replace Board Power Fuse LED 4 J1-Batteries and Motor Connector 18 Timer Pot (3 to 60 sec.
CONTROL BOARD DESCRIPTION 29 Master / 27 28 1 Slave 26 25 24 23 22 21 20 19 2 18 1 17 16 15 14 13 12 11 10 3 4 5 6 7 8 9 1 Open or Close Relay LED 15 Board Fuse 2 Control Relay LED 16 Replace Charging Power Fuse LED 3 Motor Fuse 17 Replace Board Power Fuse LED 4 J1-Batteries and Motor Connector 18 Timer Active LED 5 Strike Open LED 19 Timer Pot (3 to 60 sec.
A L A R M & M A G L O C K C O N N E C T I O N S Relay Contact Rating 0.5 A - 125 VAC 1 A - 24 VDC Use the harness provided with the unit to make your connections to these alarm outputs. Maglock Connection Alarm Connection UL Audio Alarm Connection 1 2 3 1 2 3 4 2 1 1 or 3 2 Orange Wires 2 3 4 Connect for Open Inside 1. Power - for Open Inside 2. Ground Burglar Alarm Relay Output 1. Common 2. N. O. OR Connect for Open Outside 2. Ground 3.
U L A U D I O A L A R M This UL alarm is required per UL-325. It will go off after 2 consecutive events on reverse sensor. The UL alarm will sound for a period of 5 minutes or until a new command is received by one of the commands in column A but NOT column B. 1 2 3 4 B Strike Open J3 - 7 & 12 Safety Loop J3 - 6 & 12 UL Audio Alarm B U R G L A R The control board provides a relay with a normally open contact to interface with a house alarm.
G AT E O P E N I N G “ I N S I D E ” I N S TA L L AT I O N O F. . . MAGLOCK ALARM SYSTEM ON REVERSE SENSOR ALARM SENSOR OPEN OUTSIDE REPLACE FUSE WHEN LED IS ON YES ON 60 OFF 3 TIMER POWER CHARGE OK BAT CENTRAL LOW CONTROL 1.
G AT E O P E N I N G “ O U T S I D E ” I N S TA L L AT I O N O F. . . MAGLOCK ALARM SYSTEM ON REVERSE SENSOR ALARM SENSOR OPEN OUTSIDE REPLACE FUSE WHEN LED IS ON YES ON 60 TIMER OFF 3 POWER CHARGE OK BAT CENTRAL LOW CONTROL 1.
E M E R G E N C Y K E Y R E L E A S E Step 1: To move the gate during an emergency or power failure, insert key and turn counterclockwise to Unlock the Miracle 1 from the gate. Unlock Key Provided Step 2: Move the gate manually to the full open position 90°. Full Open Position 90 Degrees Step 3: Re-Lock the operator by turning the key clockwise while pushing or pulling on the gate until you hear the key release click into place. The operator can resume normal operation as soon as power is restored.
C L O S E D E L A Y M a s t e r / S l a v e O P T I O N O n l y This option is to be used when there is a master/slave installation with overlapping gates. MASTER MAGLOCK SLAVE SYSTEM ON ALARM REVERSE SENSOR ALARM SENSOR OPEN OUT OPEN IN OFF POS STOP ON POS STOP CLOSE DLY ON CLOSE DLY OFF OFF 60 ON 3 TIMER POWER CHARGE OK BATTTERY LOW 1.
C L O S E D E L A Y O P T I O N M a s t e r / S l a v e O n l y This option is to be used when there is a master/slave installation with overlapping gates. MASTER MAGLOCK SLAVE SYSTEM ON ALARM REVERSE SENSOR ALARM SENSOR OPEN OUT OPEN IN OFF POS STOP ON POS STOP CLOSE DLY ON CLOSE DLY OFF OFF 60 ON 3 TIMER POWER CHARGE OK BATTTERY LOW 1.
T R O U B L E S H O O T I N G Check the Fuses If the gate is not moving in any direction be sure to check all of the LED displays on the control board. If the board power or charging power LEDs are on, change the corresponding fuse on the right side of the board. If the motor will not work, and all LED's on the board are ok, check the fuse on the left side of the board and replace if necessary.
T R O U B L E S H O O T I N G The Gate Will Not Close! Symptom: The radio receiver LED on the control board remains “ON” when using the remote control. Possible Solutions: Stuck remote control button. The radio receiver has malfunctioned in the “ON” position. CENTRAL CONTROL Control Board LED The Gate Will Not Open! Symptom: The radio receiver LED on the control board remains “OFF” when using the remote control. Possible Solutions: Dead battery in the remote control.
T R O U B L E S H O O T I N G You will SEE the alarm LED “ON” when... MAGLOCK M SYSTE ON ALARM SYSTEM ON REVERSE SENSOR ALARM SENSOR OPEN OUTSIDE TIMER OFF 3 POWER CHARGE OK BAT CENTRAL LOW CONTROL 2A 250V 60 SE REVEROR SENS REPLACE FUSE WHEN LED IS ON YES ON 1.
O P T I O N A L S O L A R P O W E R Elite offers a plug-in solar adapter and solar panel as an option for the Miracle 1. Simply plug in the adapter to the existing electronic control box. No other modifications are necessary. Elite's “SOLAR 3” solar panel provides solar power for the Miracle 1 single arm operator. Contact your local dealer for more information.
M I R A C L E 1 P A R T S A BT 12 Q006 A BT MIR Q227P Q222 MAGLOCK Q223 ALARM SYSTEM ON SLAVE MASTER REVERSE SENSOR SYSTEM ON ALARM MAGLOCK ALARM SENSOR REVERSE SENSOR OPEN OUTSIDE OPEN INSIDE STOP BY POSITIVE STOP REPLACE FUSE WHEN LED IS ON ALARM SENSOR YES NO OPEN IN ON OFF 60 TIMER OFF POS STOP Q162 3 POWER CHARGE OK CLOSE DLY OFF OFF 60 BATTERY LOW CENTRAL OPEN OUT ON POS STOP CLOSE DLY ON 3 TIMER CONTROL POWER CHARGE OK RADIO CENTER STRIKE SAFETY REC LOOP OPEN LOOP
M I R A C L E 1 P A R T S A BT 12 - Backup Battery L I S T A BT MIR - Plastic Rack and 2 Batteries Q233 - Bolt, Bushing, Nut (Fits Rear Mount of Operator) A POW3 - Transformer (24 VAC) Q234 - Bracket/Rod A SOLAR ADP - DC Solar Power Adapter Q239 - Limit Switch Harness (Wires and 4 Limit Switches) O-MIRACLE 1 ARM - Single Miracle 1 Arm (Complete) Q240 - Maglock Harness Q006 - Control Board Screws (Set of 3) Q242 - Alarm Harness Q162 - 1.
M I R A C L E 1 A C C E S S O R I E S 24V DC Radio Receiver Intercom System (Elite Part # A RM 201K) (Elite Part # A 1099) Transmitters 24V Photo Electric Eye (Elite Part # A 3060) (Elite Part # A 3089) Solar Panel (Elite Part # A OMRON) Wireless Programmable Digital Keyless Entry System (Elite Part # SOLAR 3) (Elite Part # A 4200) 24V DC External Loop Detectors DC Power Adapter (Elite Part # A 24) “Center Loop” “Safety Loop” (Elite Part # A SOLAR ADP) 36
F E A T U R E S A N D S P E C I F I C A T I O N S Mechanical Specifications Motor 24V DC, 12 Amps. Cycles 100 / Day. (Consult factory for solar applications) Shipping Weight: Single Unit: 58 lbs. - Master/Slave: 89 lbs Torque 600 lbs. of torque. Finishing Aluminum. Capabilities Maximum gate size 15' wide, 600 lbs. Operator Travel Speed - 14 to 18 seconds 90° opening. Top 3.5" 39.5" Front Back 4" 5.75" Side Electrical Specifications Running System - Top 5.25" 10.5" 12.