Datasheet
19
Fig. 2
Flexible swivel
Antenna360̊
Status LED
Flash Test / Flash Mode /
Congurationbutton
RX feature button
Power increase
or modelling lamp
toggle
RX feature button
Power decrease
Frequency
channel selector
MODE switch
GROUP switch
Frequency Channel
Note:
Transmitter and the corresponding Transceiver RX, the Universal Receiver or the EL units with
integrated EL-Skyport Receiver must have the same frequency channel settings!
Frequency
Channel
Slide Button conguration Frequency
/ Mhz
1 2 3
1 (default) Off Off Off 2456
2 On Off Off 2458
3 Off On Off 2460
4 On On Off 2462
5 Off Off On 2469
6 On Off On 2471
7 Off On On 2473
8 On On On 2475
EL-Skyport Sync Speed & Standard Mode
The SPEED function is available for Ranger Quadra AS, BXRi 250 / 500 und D-Lite RX ONE and all other
units, when used with the EL-Skyport Universal Speed.
Select “Speed” sync mode
Synchronises SLR cameras up to 1/250 s, or compact digital cameras up to 1/2850 s
- Select “Group” or “All” mode.
-Presstestpushbuttonforminimum5secondsuntiltheSTATUSLEDashestwotimes.
- Release test push button.
- Now the EL-Skyport Transmitter Speed works in “SPEED” mode (r.2 mode).
Select “Standard” triggering mode
Synchronises SLR cameras up to 1/200 s, or compact digital cameras up to 1/1600 s
- Select “Group” or “All” mode.
-Presstestpushbuttonforminimum5secondsuntiltheSTATUSLEDashesonetime.
- Release test push button.
- Now the EL-Skyport Transmitter Speed works in “STANDARD” mode.
EL-Skyport Module Conguration:
Only possible with EL-Skyport PC / MAC software v 3.0 and higher.
- Power-Save Timer, individual programmable or disabled.
- Trigger delay is programmable from 250 ms up to 15 s.
- Download the FREE EL-Skyport Software from www.elinchrom.com
English