Technical data
Owner’s Manual
6
2. Metal Platter - the measured loads are placed on top
3. Plastic lid cover - covers the electronic unit and the load cell unit. It protects the keyboard,
operator’s (8) and customer’s (7) display.
- The following information is also placed on the cover
- License registration
- Indications for state control
4. Leveler - for the scales to be horizontally placed adjust the legs (5) till the bubble in the leveler
indication stabilizes in the middle of the readout.
5. Adjustable legs - to level the scales by screwing them in both directions.
6. Keyboard - to enter price indication and to choose preliminary set prices.
7. Customer indication - to indicate the weight of the goods, price per kg and total price.
8. Operator’s Indication
9. Interface RS232 to connect with cash registers, PC or labeling printers.
5.3. Stamps and Lead Sealing
The scales from series EVLplus –xx LM, LT, LT, and BT have ЕО certificate for approved type and
correspond with the “Regulation for the main requirements and the measure of quality for scales with
non-automatic operation”
According to the requirements in appendix 8 from the Regulation, on the left side of the scales is
placed a label with serial number, meteorological characteristics of the scale, CE logo for
correspondence and the year of which the valuation for correspondence was done. The scales are
also stamped with two lead seals against unauthorized opening and disassemble.
6. Preparing For Use
Before installing the scale is necessary to inspect the device for any mechanical damages that may
have occurred during the transportation. After the inspection is done the scale is ready for installation.
Place the scale onto horizontal surface. Level the scale by using the 4 adjustable legs at the bottom of
the scale. Turn the legs clockwise or counterclockwise so the bubble of the leveling gauge is inside
the indicated circle which is located on the front left part of the scale.
After the scale is properly placed for work, normal working conditions should be provided:
Operating Temperature -10°C to +40°C
Air Humidity 20% to 80%
Power Source 220V
Power Source Frequency 50 Hz
DO NOT plug the AC adapter in any power source different from the 220V/50Hz!!!
Avoid overload of the scale with weights greater that the specified Maximal Load!
7. Installation Instructions
1. Open the box and pull out the contents, including: