Use and Care Manual
18
Charcoal filter inclusion and exclusion (Recirculating
accessories)
• The charcoal filter inclusion or exclusion can be set by
pressing the “+” and “-” buttons at the same time for 5
seconds.
• The Inclusion or exclusion of charcoal filter must be
selected while the lamps and the motor are OFF.
• When the charcoal filter has been excluded, the charcoal
filter alarm is disabled.
Heat sensor
• The control is equipped with a heat sensor that will turn
on the blower at second speed if excessive heat occurs
(over 158° F or 70°C) surrounding the control area.
• If the blower is OFF or if it is operating at first or second
speed, the blower will be set automatically to third
speed, the display shows the word "CArE" to indicate
that heat sensor has detected an excessive heat.
• During this state, the user may raise the blower speed to
fourth speed but can not decrease the speed.
• When the temperature level on the hood drops to
normal, the blower will operate in the setting defined by
the user before the alarm occured.