Product Manual
6.7
Maintenance
Remove and discard O-rings 5 and 6.
Remove nipple 7.
Remove parts 4 and 3.
Replace parts 3 and 4 with new parts from the service
kit.
Replace nipple 7.
Replace the new O-rings 5 and 6.
Apply teflon grease on O-rings 5 and 6.
Reassemble the complete valve.
6.1.12 Condensate drain in tank
If the duty cycle of the compressor (running hours) per
day is less than 16 hours, check for water condensation in
the air oil separator tank. When the compressor switches
off, the hot air inside the tank might condense when the
surrounding temperature lowers. In such cases, drain the
condensate from the separator tank weekly once or twice
depending on the moisture quantity. The condensate,
which is denser than oil, will settle at the lower part of the
tank.
6.1.13 Procedure for draining the
condensate
To drain the condensate in the tank:
Switch off and isolate the machine from the service line.
Unscrew the drain plug from the oil drain line.
Slightly open the drain ball valve.
Check for water in the valve outlet. Close the valve
immediately after draining the water to prevent leakage
of more oil.
Replace the drain plug. Tighten it firmly to avoid leaks.
Dispose of the drained condensate as per the local
environmental procedure.
6.1.14 Anti Vibration Mount
Anti Vibration Mount should be replaced during major
overhaul of airend or motor. If no such situation, replace
AVM every 5 years
DRAIN BALL VALVE