Product Manual

6.11
Maintenance
Problem Cause Solution (go sequentially)
No control air supply to solenoid valve Replace/connect
Loading/unloading
problem
Solenoid valve malfunctioning
1. Replace the solenoid valve assembly.
2. Clean the orifice.
No electrical supply for energizing the
solenoid valve
Replace the Neuron microcontroller.
Intake valve malfunctioning Check and replace the intake valve kit.
Blow-down valve malfunctioning
1. Clean or change the BDV assembly.
2. Clean the orifice.
MPV malfunctioning
1. Check and change the MPV kit.
2. Check and change the MPV assembly.
1. Air requirement is more than compressor
capacity
1. Replace the compressor.
2. Arrest all pipeline leakages.
1. Replace the compressor.
3. Excess pressure drop in pipeline
1. Replace the compressor.
2. Arrest all pipeline leakages.
Pressure transmitter malfunction
1. Tighten the lap cable.
Pressure transmitter malfunction
Pressure transmitter malfunction
Pressure transmitter malfunction
4. Replace the Neuron microcontroller.
Replace the Neuron microcontroller.
Disable 'unload mode' in the operator settings of the
Neuron microcontroller.
4. Replace the Neuron microcontroller
Malfunction of R04 relay (loading/ unloading
relay) in Neuron microcontroller
Replace Neuron microcontroller
Unload mode enabled in Neuron
microcontroller
Disable 'unload mode' in operator settings of Neuron
microcontroller