Product Manual

6.2
Maintenance
6.1.1 Maintenance intervals
6.1.2 Daily operation
Prior to starting the machine, check the oil level in the
separator tank. (See Starting the compressor in the
Operation section.) Should the level be low, add the
necessary amount. If you need to add oil too frequently, it
may indicate that a problem has developed which is
causing this excessive loss. Refer to the Troubleshooting
section (excessive coolant consumption) for a probable
cause and remedy.
After a routine start has been made, observe the machine
and monitor whether correct readings for that particular
phase of operation are being displayed. Good practice is to
perform a general check on the overall machine and
instruments after the machine has warmed up, to ensure
that the compressor is running properly.
Maintenance 6.1
NOTE
The above lifetime guidelines are applicable only to standard operating and regular maintenance conditions recommended in
this manual. In the event of changes in the conditions, consult ELGi.
Do not remove caps, plugs, or other components when the
compressor is running or pressurized. Stop the compressor
and relieve all internal pressure before doing so.
Frequency Part Remarks
Daily
Oil level Check
MOS condensate Check
Warning / alarms Check
Condensate in AOS tank Check
Weekly
Pre filter ( air intake, cooler, control panel) Clean
Air filter element Clean *
2000 hours or 6 months
#
Oil & after coolers - air cooled (External) Check & Clean
Oil filter Replace
Oil Sampling **
Belt tensioning Check & Re-tension
Air filter element Replace
50 Hz motor - 2 pole grease Replace
4000 hours or every year
#
Pre filter ( air intake, cooler, control panel) Replace
Oil Air lube XD / Air lube FG Replace
Air-oil separator element Air lube XD / Air lube FG Replace
50 Hz motor ( 4 pole ) grease Replace
60 Hz motor (> 25HP ) grease Replace
Return line sight glass / orifice / NRV Check & Clean
Return line strainer Check & Clean
8000 hours or every 2 years
#
Air-oil separator element - UT Synthetic Replace
Oil - UT Synthetic Replace
60 Hz motor (≤ 25HP ) grease Replace
Electrical connections Check
Pipe coupling element Replace
Intake valve kit Replace
Thermal Valve Kit Check & Replace
MPV kit Replace
BDV kit Replace
Solenoid valve Replace
Safety valve Replace
Nylon tubes Replace
10000 hours Belt Replace
#- Whichever comes first * - As per air filer clog indicator ** - For USA region only
Table 2. Maintenance intervals