User guide
15
2. Quick Setup Reference – Known Reference Satellites – NON CONUS
Step Function Action Display Page
1. Power up antenna Turn on power at ACU READY
2. Set Code (enables editing)
(Page 3.0)
From READY page
Main 2x
+ to code 13, Enter
Main 2x
READY
TECH SETUP,[Code 0]
Tech Setup [CODE 13]
READY
3. Clear existing satellite data.
(Page 3.2)
From READY page
Main 2x
Arrow 2x
+ or – to
Enter
+
Enter
READY
TECH SETUP [Code 13]
SET TEST, [NONE]
[CLEAR REF DATA]
[CANCEL]
[RUN NOW]
READY
4. Input reference satellite parameters.
(Page 2.3)
Go to reference satellites entry page
Leave both default frequencies 10799
Set scan type to Freq
Repeat, up to 12 Ref satellites
From READY page
Main 1x
Arrow 3x
Enter
+ or – to Ref Sat Long
ENTER
- to [10799]
ENTER
+ TO [Freq]
ENTER
READY
USER SETUP
[Rs 1]
[XXX.X]
[XXX.X]
[XXX.X]
[10799]
[SS]
[Freq]
5.
Run Frequency Scan
(Page 3.2 – Set Test/Freq Scan)
From READY page
Main 2x
Arrow 2x
+ or – to
ENTER
+
Enter
READY
TECH SETUP, [Code 13]
SET TEST, [NONE]
[SCAN FREQ]
[cancel]
[RUN NOW]
READY
6.
(Input Reference Satellites Page 1.1)
Select RefX Satellite
Select RefY Satellite
From Ready page:
Arrow 1x
+ or – through Ref Sat List
ENTER
+ or – through Ref Sat List
Enter
Main
READY
SetREF, X
XXX.X
SetREF, Y
XXX.X
READY
7. (Input data satellite parameters
Page 1.2)
Toggle between SatA and SatB
Input orbital position for SatA
Input orbital position for SatB
From READY page:
Arrow 2x
+ or –
+ or –
Enter
READY
SELECT DATA
[SatA] or [SatB]
XXX.X
NOTE: The factory default
setting for Reference
Satellite is AUTO. The
system will select a
reference satellite that is
optimum for your GPS
position.
Locate the antenna so that
it has an unobstructed
view of the orbital arc.
Orient the antenna so that
it comes up generally to
the south (if located north
of equator), north (if
located south of equator).
*If IDLE SAT shows 0.0,
then Satellite
Configuration has not
been performed and
system will err.
IMPORTANT