Data Sheet
42
ETHERIO24TCPDATASHEET
AbsoluteMaximumRatings
Warning!Exceedingtheseratingsmaycauseirreparabledamagetotheunit.
Parameter AbsoluteMaximumConditions
StorageTemperature ‐65°Cto+150°C
AmbientTemperature(PowerApplied) ‐40°Cto+75°C
HumidityRange 0to85%RH
PowerSupplyInputVoltage +7vto+35.00vDC
DCInputVoltage–PortInputs‐0.6vto+5.6v
DCInputCurrent–perIOPin 25m
A
DCOutputCurrent– perIOPin 25m
A
DCInputCurrent–TotalperPort 75m
A
DCOutputCurrent– TotalperPort 62.5m
A
DCCharacteristics
(Temperature=25°C,Power=24VDC)
Parameter Conditions Min Typ Max Units
PowerConsumption 1.1W
LogicLow
SchmittTrigger 0
0.75 V
LogicHigh
SchmittTrigger 4.25
5.0 V
InputLeakageCurrent Vin=0Vor5V ‐3.0 +3.0μ
A
Pull‐UpCurrent 200 400 600μ
A
OutputHighVoltage Load=14m
A
4.3 V
OutputLowVoltage Load=25m
A
0.6 V
PacketTimingCharacteristics
Duetothecharacteristicsofdifferentnetworkstheexpectedtimeto
receiveandtransmitpacketstotheunitwilldependontheindividual
networkconfigurationsandtheapplicationssendingandreceiving
commands.
Parameter Conditions Min Typ Max Units
PortWriteSpeed Multiplewriteswithinonepacket 170 μS
PortReadSpeed Multiplereadswithinonepacket 32 μS
Autoscan MinimumRateatwhichautoscan
canpickupapintoggle
10 mS
FurtherReading
InformationandcodingexamplesfortheEtherIO24TCPcanbefoundonour
websiteatwww.elexol.com
©
2013ElexolPtyLtd Revision1.3