Event: Replace Battery Now (0x0B)
Note
Mouse zapper is powered by battery. Using batteries other than specified may result
in explosion. Dispose of properly, please observe environmental protection rules.
Advanced Configuration
1. Basic Setting Command
When the mouse zapper trigger alarm, it will send basic setting command with parameters. The
receiver will execute this parameters. For example, when the lamp receive the basic setting
command, the parameters of the command decides the brightness of this lamp.
Function: Basic Set
Parameter Number: 1
Parameter Size: 1 Byte
Available Settings:0, 1 ~ 99 or 255
0 – OFF, Alarm canceling or turning a device off
1 ~ 99 or 255 – ON (Binary Switch Device)
Dim Level (Multilevel Switch Device)
Default Setting: 99
2. High Voltage Output Mode
This Parameter defines the high voltage mode when rat enter in device, there are two modes.
Always occur high voltage output and occur high voltage according to rat heartbeat frequency.
Always output high voltage: The Device will always output High voltage within 4 minutes.
Output High Voltage with Rat Heartbeat Frequency: First, the Device will output high voltage
in 1 minute, and the other 3 minutes output high voltage according to rat heartbeat frequency
(about 500 times per minute).
Function: High Voltage Mode
Parameter Number: 2
Parameter Size: 1 Byte
Available Settings: 1 – Always output high voltage
2 – Output High Voltage with Rat Heartbeat Frequency.
Battery Check Command
The users can check the battery status of the mouse zapper by sending BATTERY_GET command.
Once the mouse zapper receive the command, it will return BATTERY_REPORT command. If the
mouser zapper sends BATTERY_LEVEL = 0xFF command to the Z-Wave Controller, it shows
the mouse zapper is battery off, otherwise BATTERY_LEVEL range should be 0% to 100%.
Wake up Command Class