96
16
Quick instructions for commissioning
In Dual Driver version can be a good rule, before leaving the station, a test to switch the
reserve.
To do this, turn off the “master”exciter, disarming the breaker, and verify that the reser-
ve exciter is activated, bringing the output power to target level.
Verify, then, the reverse step, turn on the “master” exciter and turn off the reserve.
Everything works properly when switching is performed on the first exciter and power
levels return to those previous.
Now you can restore normal operation.