5.2 Factory settings
The equipment comes with the following default factory settings.
If they correspond to your requirements, just put the machine in RF ON. Should you
need to change the parameters, please refer to paragraph “Main parameter setup”.
FACTORY SETTINGS
Output power (TRG) Maximum value
Frequency 98.000 MHz (unless it is communicated by the
customer prior to Elenos another value)
Dual Driver configuration D.D.Auto : T
Retr 0 of 10
TX1 : ANT (on antenna)
TX2 : LOAD (on dummy load)
L,R input sensitivity for +/-75 kHz deviation 0dBm
MPX input sensitivity for +/-75 kHz deviation 0dBm
AUX input sensitivity 0dBm
Stereo subcarrier
19kHz
OFF (MPX input mode)
Pre-emphasis 0uS (linear)
Clipper OFF
“NO AUDIO” alarm OFF, set with non-intervention thresholds
(-25 dB for 600s)
VSWR/ROS foldback ON, threshold protection
Interlock External cable
TC/TS speed 57600 Bit per second (you can find set diffe-
rent values )
Address Set as shown in the labels affixed to the rack
The equipment comes with the programming lever in running mode.