Current
consumption @
230VAC/3-PH
110A 92A 73A 63A 42A
Current
consumption @
380VAC/3-PH
64A 53A 43A 36A 24A
Quick instructions for commissioning
Should the operator require to disconnect the equipment from the mains, go backwards
always disconnecting first the electrical plug and then removing the terminals from the
terminal board.
Elenos recommends the use of surge suppression devices for the AC lines to prevent
high voltage damage due to lighting strike near the transmitter site.
Connect the equipment’s RF output to the antenna cable (to check the equipment’s per-
formance it can be connected to a dummy load able to dissipate the power delivered by
the equipment).
WARNING: Before connecting the Antenna System Cable to the Elenos transmitter, plea-
se make sure that the cable, connectors and antenna are grounded according to manu-
facturers recommendations. Failure to have a proper Antenna Grounding System can
result in damage to the transmitter!
The failure on the Elenos transmitter caused on not properly ground antenna connection
will be not cover to the warranty.
Connect the desired audio cables.
Verify, on the rack, the presence of a connector already wired with a bridge. Without
this wiring (interlock) the device will not work.
Proceed to arm breakers.
WARNING: NEVER have RF power supplied to the equipment before making the
connection with the antenna.