Gas type ▶ NATURAL GAS LPG
Country of use ▶
AT,BG,CH
DK,ES,FI
GB,GR,HR
IE,IT,LT
LV,NO,PT
RO,SE,SI
SK,TR
DE,LU
PL BE,FR DE NL
BG,DK,EE
FI,GB,GR
HU,HR,IT
LY,MT,NL
NO,RO,SE
SI,SK,TR
AT,CH
CZ,DE
AT,BE,CH
CZ,DE,ES
FR,GB,IE
IT,NL,PT
SK,TR
CZ,LT
NL,SK
Gas Category ▶ I2
H
I2
E
I2
E+
I2ELL I2
L
/ I2
EK
I3
B/P
I3
B/P
I3+ I3+
Unit G20 G20 G20/G25 G20/G25 G25/G25,3 G30/G31
Supply pressure mbar 20 20 20 / 25 20 25 30 50 28 - 30/37 30
Burner pressure mbar 12,3 12,3 12,3 / 15,2 12,3 15,2 28,5
Gross input kW
8,5 8,5 13 8.5 / 7.0 12,0 8,5
Net input kW 11,7 11,7 10,8 /11,7 11,7 10,8 7,8
max. Heat output kW 9,7 9,7 9,7 / 8,7 9,7 8,7 6,5
min. Heat output kW 3,2 3,2 3,2 / 2,9 3,2 2,9 2,2
(Max.) Gas usage m
3
/uur 1,238 1,238 1,29 / 1,33 1,238 1,329 0,243
NOx mg/kWh
input
80 80 80 / 79 80 79 99
Pilot 446,0330,14 446,0330,07
Burnerinjection
1200 240
Type of flue C11 / C31 / C91
Additional electricity use
At rated heat output
el
max
9
-5
kW
With minimal heat emission
el
min
9
-5
kW
In standby mode
el
sb
9
-5
kW
Power requirement for the permanent pilot light
Power requirement for the permanent pilot
light (requirements applicable)
P
pilot
Does not
apply
Eiciency (NCV)
Eiciency at rated heat output η
th, nom
83 %
Eiciency at min. heat output (indicative) η
th, min
54 %
Type of heat release / control room temperature (Select one)
With electronic control of the room temperature plus week switch
Other control options
Control of the room temperature with presence detection
Control the room temperature with open window detection
With the option of remote control
With adaptive control of the start
With limitation of the operating time
G TECHNICAL DATA
The dataplate specifies for which type of gas, gas pressure and
for which country this appliance is intended. The nameplate is
attached to a chain. It must remain attached to the chain.
Note: Check whether the appliance is suitable for the gas type