Installation Manual Gas Fires Summum 100

APPENDICES
27
F CALCULATION TABLE FLUE GAS REDUCTION
The calculation table shows when you need to place a flue gas
ristrictor
Result Action
No ristrictor required
R Position the resitrictor
X No good operation guaranteed *
F.1 Horizontal terminal flue diameter F.2 Vertical terminal flue diameter
For a vertical terminal the minimal starting length is 0,5 meter
and the minimal vertical section is 1 meter.
* Perhaps the powerfan is a good solution here.
Total vertical Section
22 X X X X X X X X
21 R R X X X X X X
20 R R X X X X X
19 R R R R X X X X
18 R R R R R X X
17 R R R R R R R
16 R R R R R R R R
15 R R R R R R R R
14 R R R R R R R R
13 R R R R R R R R
12 R R R R R R R R
11 R R R R R R R R
10 R R R R R R R R
9 R R R R R R R R
8 R R R R R R R R
7 R R R R R
6 R R R R R
5 R R R R R
4 R R R R R
3.5 R R R R R
3
2.5 X
2 X X
1.5 X X X
1 X X X X
0 0,5 1 2 2.5 3.5 4 4.5 5
Total Horizontal Section
Total vertical Section
10 R R R R R R R
9 R R R R R R R
8 R R R R R R R
7 R R R R R R R
6 R R R R R R R
5 R R R R R R R
4 R R R R R R R
3.5 R R R R R R R
3
2.5 X
2 X X
1.5 X X X
1 X X X X
0.5 X X X X X X X
0 0.5 1 2 2.5 3.5 4 4.5 5
Total Horizontal Section