Installation Manual Sky Series EN
APPENDICES
33
Gas type ▶ NATURAL GAS LPG
Country of use ▶
AT,BG,CH
DK,ES,FI
GB,GR,HR
IE,IT,LT
LV,NO,PT
RO,SE,SI
SK,TR
DE,LU
PL BE,FR DE NL
BG,DK,EE
FI,GB,GR
HU,HR,IT
LY,MT,NL
NO,RO,SE
SI,SK,TR
AT,CH
CZ,DE
AT,BE,CH
CZ,DE,ES
FR,GB,IE
IT,NL,PT
SK,TR
CZ,LT
NL,SK
Gas Category ▶ I2
H
I2
E
I2
E+
I2ELL I2
L
/ I2
EK
I3
B/P
I3
B/P
I3+ I3+
Unit G20 G20 G20/G25 G20/G25 G25/G25,3 G30/G31
Supply pressure mbar 20 20 20 / 25 20 25 30 50 28 - 30/37 30
Burner pressure mbar 16 16 16/19,5 16 19,5 28,0 35,8 36 28
Gross input kW
19,7 19,7 15,7 15,7 18,1 14,2
Net input kW 17,7 17,7 14,1 14,1 16,3 12,5
max. Heat output kW 14,9 14,5 11,1 11,1 13,2 10,4
min. Heat output kW
3,4 3,4 2,1 2,1 2,3 3,0
(Max.) Gas usage m
3
/uur 1,67 1,67 1,8 1,8 1,8 0,35 0,45 0,45 0,35
NOx mg/kWh
input
19 19 15 15 16 20
Pilot 440-1650-312 440-1350-271
Burner injection 2x 380 (LogBurner)
320 (FlatBurner)
2x 140 (LogBurner)
120 (FlatBurner)
Type of flue C11 / C31 / C91
Additional electricity use
At rated heat output
el
max
9
-5
kW
With minimal heat emission
el
min
9
-5
kW
In standby mode
el
sb
9
-5
kW
Power requirement for the permanent pilot light
Power requirement for the permanent pilot
light (requirements applicable)
P
pilot
Does not
apply
Eiciency (NCV)
Eiciency at rated heat output η
th, nom
90 %
Eiciency at min. heat output (indicative) η
th, min
59 %
Type of heat release / control room temperature (Select one)
With electronic control of the room temperature plus week switch
Other control options
Control of the room temperature with presence detection
Control the room temperature with open window detection
With the option of remote control
With adaptive control of the start
With limitation of the operating time
Real Flame Burner