Installation Manual Gas Fires Modore 185
11
INSTALLATION MANUAL
P
B
L
Q
D
E
O
N
I
H
G
K
J
B
L
Q
I
H
G
D
E
M
O
K
J
6.3 Assembly regulations with flammable materials
(Figure 6.3 and 6.4)
Load-bearing walls and ceilings must be covered in a protective
fire resistant plate.
Never use flammable materials around the fireplace or cove.
The minimal distance between the device and non-flammable
materials must be at 50 mm to ensure a convection air flow.
Make sure there is a good air ventilation in the cove. The
temperature that leaves through the ventilation grilles must not
be higher than 85°C. Therefore one should always make sure
there are enough ventilation grilles in the upper and lower parts
of the cove.
6.3.1 Hot air outlets and ventilation grilles
The ventilation grilles are to be placed at a minimal distance of
20cm from the ceiling and 30cm from any built-in furniture from
the side, any flammable material or load-bearing concrete parts.
To avoid heat accumulation in the cove a non-flammable false
ceiling is to be placed directly above the grilles. The ventilation
grilles need to be easy to clean at all times.
6.3.2 Floor protection
Between the device and the ground a minimal distance of
10cm is to be taken into account. The temperature of the floor
under the device needs be less than 85°C and the floor of the
conversion around the fireplace is to be constructed of non-
flammable materials. If necessary the floor is to be covered with
an insulation layer to protect it from unauthorized temperatures.
6.3.3 Radiation
When the fireplace is turned on, heat radiation will escape
through the ceramic glass and will heat up the environment.
Therefore it is important that a minimal distance between
the ceramic glass and any flammable material in front of the
fireplace is 40cm.
6.3.4 Electrical pipes
The conversion has to be free of the usual electric installation
pipes, if these are not protected against temperatures over
30°C by the necessary precautions. Special pipelines with an
heightened heat resistance are permitted.
Figure 6.3 - Top Right
C11 - Flue situatie Flammable material
Figure 6.2- Bottom Left
C31 - Flue situatie Non-Flammable material
Figure 6.2- Top Left
C31 - Flue situatie Non-Flammable material
Figure 6.4 - Bottom Right
C31 - Flue situatie Flammable material