User Manual

THE MIDI SEQUENCER
116
simultaneously it is possible to adjust the note offset values of more than one arpeggiator
step at a time.
Arpeggiated notes and any note offsets can be forced to play according to a given key
scale. The F knob sets the key scale. When set to OFF all notes and note offsets will play
according to the set notes. This setting will affect the note trigs of the track even if the
MODE setting fo und in the ARPEGGIATIOR MAIN menu is set to OFF
[FUNCTION]+[LEFT]/[RIGHT] can be used to rotate the arpeggiator sequence.
The arpeggiator sequence settings can be copied, cleared and pasted.
MIDI LFO MAIN
The MIDI LFOs work mo re or less the same way as the audio LFOs. The difference is th at
they are exclusive to the MIDI tracks. F or info about ho w the LFO p aramete rs work, please
see “LFO MAIN” on page 70.
MIDI LFO SETUP
The MIDI LFO SETUP pages funct ion just like th e LF O SETUP pages for the audi o LF O s.
Please see “LFO SETUP” on page 70 for parameter explanations.
The MIDI LFO designer waveforms are only available to the MIDI tracks.
CTRL 1 MAIN
Here pitch bend, af ter touch and th e values of up to four a ssignable CC commands are set.
The default value of the parameters is OFF, meaning they are disabled and won’t se nd out
any data. Holding [FUNCTION] and pressing the DATA ENTRY knobs will enable them.