User Manual

9. TRACK RELATED PARAMETERS
31
9. TRACK RELATED PARAMETERS
Here follows a description of all of the parameters that are available to change the character and behavior
of the track’s samples.
9.1 PARAMETER EDITING
The TRACK PARAMETER knobs are used to change the values of the track parameters.
9.1.1 PARAMETER VALUE JUMP
Pressing [FUNC] while editing specific parameters makes the parameter values jump to appropriate
positions. For example, sample PITCH jumps whole octaves.
9.1.2 PARAMETER REVERT FUNCTION
If you have changed a parameter setting, you can press [BACK]
to revert that change to the parame-
ters previous setting. This function has a time-out function, meaning that, after you adjusted the param-
eter, you have roughly three seconds to perform the revert operation before the change is permanent.
Changes made by setting parameter locks are revertable as long as you keep the [TRIG] key pressed.
9.1.3 CONTROL ALL
If you press and hold [TRACK] and use the TRACK PARAMETER knobs to change a parameter setting,
this change aects this parameter in all the tracks in the pattern. You can also use the Parameter Revert
function on Control All operations.
The Control All operation is also available for the track LEVEL/PAN and also for the LOOP
and REVERSE settings.
9.2 TRACK PARAMETERS
The track parameters may be parameter locked to other settings on any step of the pattern by (in GRID
RECORDING mode) first pressing and holding a [TRIG] key, and then changing the parameters’ settings
with the TRACK PARAMETER knobs. For more information, please see “8.12.1 PARAMETER LOCKS” on
page 26.
9.2.1 PITCH
Sample Pitch sets the tuning of the sample. This parameter is bipolar, and a value of 0 leaves the pitch
unchanged. (-24–+24, equivalent to four octaves.)
9.2.2 DECAY
Amp Decay sets the length of the decay phase of the amp envelope. (0–126, INF)
9.2.3 SAMPLE START
Sample Start sets the start position for playback of the sample. (0–120)
9.2.4 SAMPLE LENGTH
Sample Length sets the length of the playback of the sample. The Sample Length is defined from the
Sample Start position, so if you change the Sample Start value, you also change the Sample Length
position. (0–120)
The SAMPLE START and SAMPLE LENGTH parameters with LOOP set to ON.
Sample
Start
Sample Length
9.2.5 CUTOFF
Filter Cuto sets the cuto frequency of the low-pass/high-pass filter. Negative parameter values make
the filter function as a low-pass filter. Positive parameter values make the filter function as a high-pass
filter. (-64–+63)