User Manual
10. THE SEQUENCER
42
10.7 ARPEGGIATOR SETUP
Pressing [FUNC] + [ARP] opens the ARPEGGIATOR SETUP menu. Here the arpeggiator length and note
osets are set.
Select the length of the arpeggio by turning DATA ENTRY knob E. The max length is 16 sequencer steps.
The <TRIG LEDS> indicate the length of the arpeggio and, when the arpeggio is playing, the number of
played arpeggio notes.
Arpeggio note osets can be inserted by pressing a [TRIG] key and turning DATA ENTRY knob J. By press-
ing several [TRIG] keys simultaneously it is possible to adjust the note osets of more than one step.
10.8 NOTE MENU
The NOTE menu controls general note settings for the active track. Open by pressing [NOTE]. NOTE menu
settings are a part of the pattern, and they are not stored together with kits.
The parameter settings seen in the NOTE menu settings are the default settings when placing trigs on the
sequencer. Entering three note trigs, changing, for example, the note length parameter and then entering
three more note trigs will thus make the last three note trigs share a dierent note length compared to
the first three. To add individual settings per note, utilize parameter locks. For more information, please
see “10.12.1 PARAMETER LOCKS” on page 45. µTM, ENV, and LFO settings can only be changed when
parameter locked.
10.8.1 NOT
Sets the default note value.
10.8.2 VEL
Sets the velocity value. The higher the value, the higher the volume of the note. The default value is 100.
Please note that this value will aect any VELOCITY MOD menu assignments. For more information,
please see “9.11.6 VELOCITY MOD” on page 34.
10.8.3 LEN
Sets the note length.
10.8.4 µTM
Controls the micro timing oset. A negative value will nudge the trig to a position before the quantized
sequencer step, a positive after. Each micro timing value step is equal to one 1/384th of a note. When
entering note trigs in the LIVE RECORDING mode, they will automatically be micro timed. For more infor-
mation, please see “10.3.3 LIVE RECORDING MODE” on page 39.
10.8.5 TRC
Trig Condition is a set of conditional rules can be applied to any trig, using a parameter lock. Each setting
is a logical condition, which will determine whether or not the sequencer note will be triggered.