User Manual

Table Of Contents
THE SEQUENCER
31
Press the [PAGE] key for quickly changing the total length of the pattern. Press the [TRIG] keys to
quickly change the number of steps of the pattern.
A 2X time signature setting is useful for increasing the base resolution of the step sequencer to
32nd notes. A 3/4X setting is useful when the Analog Four is playing alongside other instruments
set to the same BPM and you want the Analog Four to play triplets.
ADVANCED MODE
In this mode the tracks of the pattern can be assigned individual lengths. Select this mode by navigating to the
SCALE column using the [LEFT] arrow key. Select ADVANCED by using the [DOWN] arrow. In ADVANCED
mode, three columns exist, SCALE, TRACK and MASTER.
The scale settings made while this mode is activated will only affect the active track. Press the [TRACK] keys to
select the track whose scale settings should be edited.
The TRACK column works just like the PATTERN column in NORMAL mode, but on a per track basis.
The MASTER column is only available in ADVANCED mode. Here the amount of steps the pattern will play
before all tracks are restarted, plus the general time signature of the pattern, is set. The leftmost setting controls
the amount of steps the pattern will play before all tracks are restarted. An INF setting will make the tracks of the
pattern loop infinitely, without being restarted. Note that this setting also affects for how long the active pattern
will play before a chained pattern will start playing. The rightmost setting sets the general time signature of the
pattern.
If INF is selected the active pattern will play infinitely, making it impossible to change to another
pattern.
Press [FUNCTION] + [UP]/[DOWN] to set the MASTER LENGTH in increments of 16.