PSB 9000 2.5 kW Series
3.11.16.1 Settings for the static discharge mode
Thefollowingparameterscanbeconguredforthestatic discharge battery test function:
Value Range Description
I 0...I
Nom
Maximum discharge current (in Ampere)
P 0...P
Nom
Maximum discharge power (in Watt)
R R
Min
..R
Max
| OFF MaximumdischargeresistanceinΩ
3.11.16.2 Settings for the dynamic discharge mode
Thefollowingparameterscanbeconguredforthedynamic discharge battery test function:
Value Range Description
I
1
0...I
Nom
Upper/lower current setting for pulsed operation (the higher value of
both is automatically used as upper level)
I
2
0...I
Nom
P 0...P
Nom
Maximum discharge power (in Watt)
t
1
1 s ... 36000 s
t1 = Time for the upper level of the pulsed current (pulse)
t2 = Time for the lower level of the pulsed current (pause)
t
2
1 s ... 36000 s
3.11.16.3 Settings for the static charge mode
Thefollowingparameterscanbeconguredforthestatic charge battery test function:
Value Range Description
U
Charge
0...U
Nom
Charging voltage (in Volt)
I
Charge
0...I
Nom
Maximum charging current (in Ampere)
3.11.16.4 Settings for the dynamic test mode
Thefollowingparameterscanbeconguredforthedynamic test battery test function:
Value Range Description
I
Charging end current
0...I
Nom
Threshold (in Ampere) to stop charging
I
Charge
0...I
Nom
Static charging current (in Ampere)
U
Charge
0...U
Nom
Charging voltage (in Volt)
t
1
1 s ... 36000 s Period for the charging test part (max. 10 h)
U
Discharge end voltage
0...U
Nom
Voltage (in Volt) to discharge the battery to (U-DV)
I
Discharge
0...I
Nom
Static discharging current (in Ampere)
t
2
1 s ... 36000 s Period for the discharging test part
Start with Charge | Discharge Determines whether the test starts with charging or discharging part
Test cycles 1...999|∞ Number of cycles to run the complete test
Rest time 1 s ... 36000 s Time to rest the test before the next cycle
3.11.16.5 Other settings
Thesesettingsareusedinalltestmodes,somewiththesamemeaningbutdi󰀨erentname:
Value Range Description
Charging end
current
0...I
Nom
Threshold (in Ampere) to stop charging in static charge mode
Discharge end
voltage
0...U
Nom
Threshold (on Volt) to let the discharging stop in static discharging or
dynamic discharging modes
Charge time
Discharge time
Battery test
time
0...10 h Test time after which the test can stop automatically. This stop criteria is
optional, it means that single tests can also run longer than 10 h.
Charge capac-
ity
Discharge ca-
pacity
0...99999.99 Ah Threshold for the max. capacity to consume from or feed to the battery
and after which the test can stop automatically. This is optional, so that
also more battery capacity can be consumed or supplied.