How to load a sequence table from an USB stick:
1. Do not plug the USB drive yet or remove it.
2. Access the function selection menu of the function generator with
MENU -> Function Generator -> Arbitrary -> U/I, to see the main screen
of sequence point selector, as depicted to the right.
3. Tap touch area , then and follow the instructions
onscreen.Ifatleastonevalidleshasbeenrecognized(forleand
pathnamingseeabove),thedevicewillshowalistoflestoselect
from with .
4. Tap touch area inthebottomrightcorner.Theselectedleisthencheckedandloaded,if
valid.Incaseitisn’tvalid,thedevicewillshowanerrormessage.Thenthelemustbecorrectedandthe
steps repeated.
How to save a sequence table to an USB stick:
1. Do not plug the USB stick yet or remove it.
2. Access the function selection menu of the function generator via MENU -> Function Generator -> Arbitrary
3. Tap on , then . The device will request you to plug the USB stick now.
4. Afterpluggingit,thedevicewilltrytoaccessthestickandndthefolderHMI_FILESandreadthecontent.
IftherearealreadyWAVE_UorWAVE_Ilespresent,theywillbelistedandyoucaneitherselectonefor
overwriting with , otherwise select foranewle.
5. Finally save the sequence table with .
3.11.11 Ramp function
Restrictions which apply particularly to this function:
• There is no preselection to which of both, source mode and sink mode, the function is applied to; the settings
decide whether it’s “source mode only”, “sink mode only” or a mixture of both
• When applying the function to the voltage, the device can only switch to and work in sink mode if the external
voltageon theDCterminalishigherthan thehighestpoint(o󰀨set+amplitude)ofthewaveandthe current
setting “I Sink” isn’t 0
Thefollowingparameterscanbeconguredforarampfunction:
Value Range Description
Ustart / Uend 0...U
Nom
Start/end value in U mode
Istart / Iend -I
Nom
...+I
Nom
Start/end value in I mode
t1 0,1 ms...36000 s Time before ramp-up or ramp-down of the signal.
t2 0.1 ms...36000 s Ramp-up or ramp-down time
10 h after reaching the ramp end, the function will stop automatically (i.e. I = 0 A, in case the
ramp was assigned to the current), unless it has been stopped manually before.