PSB 9000 2.5 kW Series
Thesedevicealarmscan’tbeconguredandarebasedonhardware:
Short Long Description Indication
PF Power Fail
AC supply over- or undervoltage. Triggers an alarm if the AC supply is
outofspecicationorwhenthedeviceiscutfromsupply,forexample
whenswitchingitowiththepowerswitch.TheDCterminalwillbe
switchedo.
Display, analog &
digital interface
OT
OverTem-
perature
Triggers an alarm if the internal temperature reaches a certain limit.
TheDCterminalwillbeswitchedo.
Display, analog &
digital interface
MSP
Master-Slave
Protection
Triggers an alarm if the master unit loses contact to any slave unit.
TheDC terminalwill beswitched o.The alarmcan becleared by
reinitializing the MS system.
Display, digital
interface
SOVP
Safety
OverVoltage
Protection
Only featured in the 60 V model:
Triggers a special OVP alarm if the voltage on the DC terminal exceeds
the rigid threshold of 101% rated voltage. The DC terminal will be
switchedo.Fordetailsrefertosection3.4.6
Display, analog &
digital interface
► How to congure the device alarms
1. WhiletheDCterminalisswitchedotapthetoucharea on the main screen.
2. On the right side tap the arrow to select “3. Protect Src” (for source mode) or “4. Protect Sink” (for sink mode).
3. Set the limits for the equipment alarm relevant to your application if the default value of 110% is unsuitable.
The set values can be entered using the ten-key tab. This will appear after tapping the touch
area “Direct input”.
The user also has the possibility of selecting whether an additional acoustic signal will be sounded if an alarm or
userdenedeventoccurs.
► How to congure the alarm sound (also see “„3.5.3. Conguration via MENU“)
1. WhiletheDCterminalisswitchedotapthetoucharea on the main screen.
2. In the menu page, tap “HMI Settings”.
3. In the following menu page, tap “Alarm Sound”.
4. Inthesettingspagetaponthesymboltoeitherenableordisablethealarmsoundandconrmwith .
3.7.2.1 User dened events
Themonitoringfunctionsofthedevicecanbeconguredforuserdenedevents.Bydefault,eventsaredeacti-
vated (action = NONE). Contrary to device alarms, the events only work while the DC terminal is switched on. It
means,forinstance,thatyoucan’tdetectundervoltage(UVD)anymoreafterswitchingtheDCterminaloand
the voltage is still sinking.
Thefollowingeventscanbeconguredindependentlyandseparatelyforsinkandsourcemodeandcan,ineach
case, trigger the actions SIGNAL, WARNING or ALARM.
Event Meaning Description Range
UVD UnderVoltage Detection
Triggers an event if the DC voltage falls below the de-
nedthreshold.
0 V...U
Nom
OVD OverVoltage Detection
TriggersaneventiftheDCvoltageexceedsthedened
threshold.
0 V...U
Nom
UCD UnderCurrent Detection
Triggers an event if the DC current falls below the de-
nedthreshold.
0 A...I
Nom
OCD OverCurrent Detection
TriggersaneventiftheDCcurrentexceedsthedened
threshold.
0 A...I
Nom
OPD OverPower Detection
TriggersaneventiftheDCpowerexceedsthedened
threshold.
0 W...P
Nom