PSB 9000 2.5 kW Series
File name Description Section
battery_test_log_<nr>.csv File with log data recorded from the battery test function. For
abatterytestlog,datadi󰀨erentand/oradditionaltologdataof
normal USB logging is recorded.
3.11.16.7
mpp_result_<nr>.csv Result data from MPP tracking mode 4 in form of a table with 100
data groups (Umpp, Impp, Pmpp)
3.11.17.6
psb_pv<nr>.csv PF function table data, as calculated by the device. Can be
loaded again.
3.11.13
psb_fc<nr>.csv FC function table data, as calculated by the device. Can be
loaded again.
3.11.14
pv_record_<nr>.csv Data from the data recording option in the extended PV function
according to EN 50530.
3.11.15.7
1.9.7 USB port (rear side)
The USB port on the back side of the device is provided for communication with the device
andforrmwareupdates.TheincludedUSBcablecanbeusedtoconnectthedevicetoa
PC (USB 2.0 or 3.0). The driver is delivered with the device and installs a virtual COM port.
Details about remote control can be found in form of a programming guide on the included
USB stick or on the web site of the manufacturer.
The device can be addressed via this port either using the international standard ModBus
RTU protocol or by SCPI language. The device recognises the message protocol used
automatically.
If remote control is in operation the USB port has no priority over either the interface module
(see below) or the analog interface and can, therefore, only be used alternatively to these.
However, monitoring is always available.
1.9.8 Interface module slot
This slot on the back side of the device (only with standard models, units with option 3W
installedaredi󰀨erent)isavailableforvariousmodulesoftheIF-ABinterfacemoduleseries.
The following options are available:
Article number Name Description
35400100 IF-AB-CANO CANopen, 1x Sub-D 9pole male
35400101 IF-AB-RS232 RS 232, 1x Sub-D 9pole male (null modem)
35400103 IF-AB-PBUS ProbusDP-V1Slave,1xSub-D9polefemale
35400104 IF-AB-ETH1P Ethernet, 1x RJ45
35400105 IF-AB-PNET1P ProNETIO,1xRJ45
35400107 IF-AB-MBUS1P ModBus TCP, 1x RJ45
35400108 IF-AB-ETH2P Ethernet, 2x RJ45
35400109 IF-AB-MBUS2P ModBus TCP, 2x RJ45
35400110 IF-AB-PNET2P ProNETIO,2xRJ45
35400111 IF-AB-CAN CAN 2.0 A / 2.0 B, 1x Sub-D 9-pole, male
35400112 IF-AB-ECT EtherCAT, 1x RJ45
Themodulescanbeinstalledbytheuserandhenceretrottedwithoutproblem.Armwareupdateofthedevice
may be necessary in order to recognize and support certain modules.
If remote control is in operation the interface module has no priority over either any other interface and can, there-
fore, only be used alternately to these. However, monitoring is always available.
Switchyourdeviceo󰀨beforeaddingorremovingmodules!