User Manual
5.2 Visualisation
5.2.1 Introduction
Visualisation (or: the graph) is a graphical display of set values and actual values in a temporal
progression. The displayed time period (X axis) can be varied between 1 second and 10 minutes
in 4 steps, as long as the graph is stopped. The window „Visualisation“ can be accessed via the
menu „Actions“ „Graph“ resp. „Graph output 1“ or „Graph output 2“. The graph is either ma-
nually started/stopped or can automatically run if sequencing and/or logging is started (also see
sections 4.6 and 5.1). The window can be maximised to have a bigger graph area.
Overview:
Figure 20
Explanation of the control elements:
▪ Time Range
Temporarily selects the time range for the graph‘s X axis. 1s, 10s, 1m or 10m.
▪ Start
Starts the graphical visualisation
▪ Stop
Stops the graphical visualisation
▪ Reset
Resets and clears the graph
▪ U set visible
Denes, if the plot of the voltage set value is displayed in the graph or not
▪ I set visible
Denes, if the plot of the current set value is displayed in the graph or not
▪ U actual visible
Denes, if the plot of the actual voltage is displayed in the graph or not
▪ I actual visible
Denes, if the plot of the actual current is displayed in the graph or not