Minute - Together with columns F, H und I, it denes the time for the actual row in
format H:M:S,MS. That time has to elapse until the next row is processed.
Allowed value range: 0…59 (integers only)
Second - Together with columns F, G und I, it denes the time for the actual row in
format H:M:S,MS. That time has to elapse until the next row is processed.
Allowed value range: 0…59 (integers only)
Millisecond - Together with columns F bis H, it denes the time for the actual row in
format H:M:S,MS. That time has to elapse until the next row is processed.
Allowed value range: 0 or 500
Following requirements for the sequence le:
• The set values for voltage and current have to be given in every row, even if only the output
is switched off
• The set values for voltage and current have to be within the nominal values of the device
and their product according to P = U * I must not exceed the device‘s nominal power
• Minimum time per row: 500ms
• Step width: minimum 500ms
• Maximum time per row: 24h 59min 59sec 500ms
• CSV le format with entries seperated by semicolons
5.1.3 Details about the sequence le for double output models (Triple)
The sequence le structure for Triple models is almost the same as for Single models, except
here it requires another row „Output select“. This row selects if the values/condition in the row are
either sent to output 1, output 2 or both. In case the row selects both outputs, the tracking mode
feature is activated for the current row.
The required format of the sequence le is dened like this:
Description of row „Output select“:
1 = Values in the row are sent to output 1 only
2 = Values in the row are sent to output 2 only
12 = Values in the row are sent to both output, but with a small skew of a few milliseconds, becau-
se tracking mode is activated before the set values are sent
Any other value or term in this column will cause the program to send the set values to output 1.