User Manual

Minute - Together with columns F, H und I, it denes the time for the actual row in
format H:M:S,MS. That time has to elapse until the next row is processed.
Allowed value range: 0…59 (integers only)
Second - Together with columns F, G und I, it denes the time for the actual row in
format H:M:S,MS. That time has to elapse until the next row is processed.
Allowed value range: 0…59 (integers only)
Millisecond - Together with columns F bis H, it denes the time for the actual row in
format H:M:S,MS. That time has to elapse until the next row is processed.
Allowed value range: 0 or 500
Following requirements for the sequence le:
• The set values for voltage and current have to be given in every row, even if only the output
is switched off
• The set values for voltage and current have to be within the nominal values of the device
and their product according to P = U * I must not exceed the device‘s nominal power
• Minimum time per row: 500ms
• Step width: minimum 500ms
• Maximum time per row: 24h 59min 59sec 500ms
• CSV le format with entries seperated by semicolons
5.1.3 Details about the sequence le for double output models (Triple)
The sequence le structure for Triple models is almost the same as for Single models, except
here it requires another row „Output select“. This row selects if the values/condition in the row are
either sent to output 1, output 2 or both. In case the row selects both outputs, the tracking mode
feature is activated for the current row.
The required format of the sequence le is dened like this:
Description of row „Output select“:
1 = Values in the row are sent to output 1 only
2 = Values in the row are sent to output 2 only
12 = Values in the row are sent to both output, but with a small skew of a few milliseconds, becau-
se tracking mode is activated before the set values are sent
Any other value or term in this column will cause the program to send the set values to output 1.