User Manual
▪ Log interval
Denes the interval to write log data into the log le.
Minimum: 0.5s
Step width: 0.5s
Default setting: 0.5s
The log interval input box uses the time format 00:00:00,0, which means HH:MM:SS,MS.
If entering, for example, 00:00:00,5 this will result in 0.5s log interval or with 00:10 it will be
10 minutes or if just entering 1 it will be 1 hour.
▪ Start logging automatically with sequencing
Denes, if data logging is automatically started together with the start of sequencing. The
le, as selected in options, will be written according to the log le action setting. If no log le
is selected, logging won‘t start. Default setting: deactivated.
Important: in order to start logging automatically, a log le has to be selected in the Options.
▪ Stop logging automatically with sequencing
Denes, if data logging is automatically stopped at the end or manual stop of sequencing.
Default setting: deactivated.
▪ Stop logging on errors
Denes if the data logging shall stop automatically when errors like overtemperature occur.
If the option is not activated, the log le will record the error in every log data row as long
as it is persistent and logging is running. Default setting: deactivated.
▪ Log le action
Denes, how the log le, which was selected by the buttons „New“ or „Open“ above in „Log
le path, is handled:
Overwrite Overwrites old log data in the selected log le everytime logging is
started.
Attention!! Old log data is deleted without further notice!
Attach Attaches data of the next logging to former data in the selected log
le. If the number of logged data rows exceeds the limit of 65450 per
log le, a new log le is created with a name extension like _001,
_002 etc., in order to uninterruptedly continue to log data. The last le
created from that rule is then used in the options in „Log le name“ and
will automatically be used for next logging and with the selected log le
action.
Default setting: Overwrite