User Manual
4.6 Options
Menu item „Options“ is used to do settings for the application, the data logging, the sequencing
and the visualisation (graph).
• Logging options
Settings for data logging feature. For PS 2000 B models with two main outputs, logging is se-
perate for each output.
Figure 15
▪ Log le path
Button New opens a „Save as...“ dialogue in order to create a new log le. The log le is
then used to write log data. The data in the log is either overwritten as soon as the next
logging is started or it is attached to the end, depending on the selected log le action
(see below).
Button Open opens an existing le for either overwriting or attaching of data.
Note: the log le is created as a so-called CSV le, where data entries are seperated
by semicolons. One le will contain a maximum of 65450 rows of log data in order to
maintain compatibility to MS Excel. In case logging exceeds that number, a new log le
is created, which will have a counter like _001, _002 etc. added to the le name. The last
log le created by that rule is then used as next log le in the options.
▪ Log le name
Only shows the log le name.