1.10.6.3 Rotary knobs
As long as the device is in manual operation, the two rotary knobs are used to adjust set values, as well
as setting the parameters in the pages SETTINGS and MENU. For a detailed description of the individual func-
tions see section „3.3 Manual operation“ on page 39. Both rotary knobs have an additional pushbutton function
whereby the decimal position of the value to be set is moved. In this way, for example, the set current value for a
device with nominal 510 A can be adjusted in increments of 10 A or possibly 0.1 A. (see also „1.10.6.2 Pushbut-
tons“ on page 25)
1.10.6.4 Resolution of the displayed values
In the display, set values can be adjusted in variable increments. The number of decimal places depends on the
device model. The values have 3 to 5 digits. Actual and set values always have the same number of digits.
Adjustment resolution and number of digits of set values in the display:
Voltage,
OVP, UVD, OVD,
U-min, U-max
Current,
OCP, UCD, OCD,
I-min, I-max
Power,
OPP, OPD,
P-max
Resistance,
R-max
Nominal
Digits
Min.
Incre-
ment
Nominal
Digits
Min.
Incre-
ment
Nominal
Digits
Min.
Incre-
ment
Nominal
Digits
Min. In-
crement
40 V / 80 V 4 0.01 V 20 A / 30 A 4 0.01 A 3.3 kW 3 0.01 kW 2Ω/3,5Ω 4 0.001Ω
200 V 5 0.01 V 40 A / 60 A 4 0.01 A 5 kW 3 0.01 kW 5Ω/7Ω 4 0.001Ω
360 V / 500 V 4 0.1 V 70 A / 80 A 4 0.01 A 6.6 kW 3 0.01 kW 14Ω/28Ω 5 0.001Ω
750 V 4 0.1 V 90 A 4 0.01 A 10 kW 4 0.01 kW 42Ω/85Ω 4 0.01Ω
1000 V 5 0.1 V 120 A / 140 A 4 0.1 A 15 kW 4 0.01 kW 90Ω 4 0.01Ω
1500 V 5 0.1 V 210 A 4 0.1 A 135Ω/166Ω 5 0.01Ω
340 A 4 0.1 A 250Ω/270Ω 5 0.01Ω
510 A 4 0.1 A 375Ω/500Ω 4 0.1Ω
562Ω 4 0.1Ω
1000Ω/1125Ω 5 0.1Ω
1500Ω 5 0.1Ω
In manual operation every set value can be set in the increments given above. In this case
the actual output values set by the device will lie within percentage tolerances as shown in the
technical data sheets. These will inuence the actual values.
1.10.6.5 USB-Port (Front side)
ThefrontalUSBport,locatedtotherightoftherotaryknobs,isintendedfortheconnectionofstandardUSBash
drives(ashdrive).Thiscanbeusedfor:
• Loading or saving sequences for the arbitrary and loading tables for the UI-IU function generator
• UpdatingHMIrmware(newlanguages,functions)
USBashdrivesmustbeFAT32 formatted and have a maximum capacity of 32GB.Allsupportedlesmust
be held in a designated folder in the root path of the USB drive in order to be found. This folder must be named
HMI_FILES, such that a PC would recognise the path G:\HMI_FILES if the drive were to be assigned the letter
G.Thecontrolpaneloftheelectronicloadcanreadthefollowingletypesfromaashdrive:
*.bin Firmware updates only for the control panel.Thelenameformatisgivenlike
96230058_FW-BE1_V114.bin, listed in short form as FW-BE1_V114.bin. Other
leswon’tberecognisedorlisted.
wave_u<arbitrary>.csv
wave_i<arbitrary>.csv
Function generator arbitrary curve for voltage (U) or current (I)
The name must begin with wave_u / wave_i,therestisuserdened.
iu<arbitrary>.csv IU table for the function generator.
The name must begin with iu,therestcanbeuserdened.
ui<arbitrary>.csv UI table for the function generator.
The name must begin with ui,therestcanbeuserdened.