PSI 9000 2U Series
Alarm Meaning Description Indication
OT
OverTem-
perature
Triggers an alarm if the internal temperature exceeds a certain limit. The
DC output will be switched off.
Display, analog
IF, digital IF
► How to congure the device alarms
1. Tap the touch area on the main screen.
2. On the right side tap the white arrow to select “2. Protect”.
3. Set the limits for the equipment alarm relevant to your application if the default value of 110% is unsuitable.
The set values can be entered using the ten-key tab. This will appear by tapping the touch area
that shows the rotary knob assignments.
The user also has the possibility of selecting whether an additional acoustic signal will be sounded if an alarm or
userdenedeventoccurs.
► How to congure the alarm sound (also see “„3.3.3. Conguration via MENU“)
1. Tap the touch area on the main screen
2. In the menu page, tap “HMI Settings”
3. In the following menu page, tap “Alarm Sound”
4. In the settings page select “Sound on “ or “Sound off”andconrmwith .
3.5.2.1 User dened events
Themonitoringfunctionsofthedevicecanbeconguredforuserdenedevents.Defaultisthatthisisdeactivated
(action=NONE).Thefollowingeventscanbeconguredindependentlyandcan,ineachcase,triggertheactions
NONE, SIGNAL, WARNING or ALARM.
Event Meaning Description Range
UVD UnderVoltage Detection
Triggers an event if the output voltage falls below the
denedthreshold.
0 V...U
Nom
OVD OverVoltage Detection
Triggers an event if the output voltage exceeds the de-
nedthreshold.
0 V...U
Nom
UCD UnderCurrent Detection
Triggers an event if the output current falls below the
denedthreshold.
0 A...I
Nom
OCD OverCurrent Detection
Triggers an event if the output current exceeds the de-
nedthreshold.
0 A...I
Nom
OPD OverPower Detection
Triggers an event if the output power exceeds the de-
nedthreshold.
0 W...P
Nom
These events should not be confused with alarms such as OT and OVP which are for device
protection. User dened events can, however, if set to action ALARM, switch off the DC output
and thus protect the load, like a sensitive electronic application.
► How to congure user dened events
1. Tap the touch area on the main screen..
2. On the right side tap the white arrows to select “4.1 Event U” or “4.2 Event I” or
“4.3 Event P”.
3. Set the monitoring limits with the left hand rotary knob and the triggered action with the right hand knob
relevant to the application (also see „3.5.1. Denition of terms“).
4. Accept the settings with .