PSI 9000 2U Series
IF Level 1 Level 2 Level 3 Description
Pronet/IO, 1 & 2 Port
IP Settings DHCP The IF allows a DHCP server to allocate an IP address, a subnet
mask and a gateway. If no DHCP server is in the network then net-
workparameterswillbesetasdenedinpoint“Manual”
Manual IP This option is activated by default. An IP address can be maually
allocated.
Gateway Here a gateway address can be allocated if required..
Subnet Hereasubnetmaskcanbedenedifthedefaultsubnetmaskis
not suitable.
DNS 1 HeretheaddressesoftherstandsecondDomainNameServers
(DNS)canbedened,ifneeded.ADNSisonlynecessaryifthe
device has Internet access and should call Internet URLs, e.g. an
internal eMail system, in order to send an eMail.
DNS 2
Port Range: 0...65535. Default ports:
5025 = Modbus RTU (for Modbus & SCPI)
Host name Free choice of host name (default: Client)
Domain name Free choice of Domain (default: Workgroup)
SMTP
Settings
Server IP Mail server address, used to send eMails via this mail server, in
order to e.g. report an alarm.
Username Login to Mailserver, Username
Password Login to Mailserver, Password
Function Tag Stringinputboxforauser-denabletextwhichdescribesthePronetslavefunctiontag.
Max. length: 32 characters
Location Tag Stringinputboxforauser-denabletextwhichdescribesthePronetslavelocationtag.
Max. length: 22 characters
Station Name String input box for a user-denable text which describes the Pronet station name.
Max. length: 54 characters
Description Stringinputboxforauser-denabletextwhichdescribestheProbusslave.
Max. length: 54 characters
Installation Date Stringinputboxforauser-denabletextwhichdescribestheProbusslaveinstallation
date tag. Max. length: 40 characters
IF Level 1 Description
Devicenet
Node Address Selection of the Devicenet node address in the range 0...63 via direct input
Baud Rate Selection of the data communication speed with 125 kbps, 250 kbps or 500 kbps (1 kbps
= 1024 Baud) as bus baud rate. Selection „AUTO“ will let the slave device wait for the
mastertoinitiatebustrafcinordertodetectthebaudrateonthebusautomatically
IF Level 1 Level 2 Description
CANopen
Node Address Selection of the CANopen node address in the range 1...127 via direct input
Baud Rate AUTO Automatic detection of the bus baud rate.(speed)
LSS Automatically sets baud rate and node address
Manual Manual selection of the baud rate that is used by the CANopen interface.
Possible selections: 10 kbps, 20 kbps, 50 kbps, 100 kbps, 125 kbps, 250
kbps, 500 kbps, 800 kbps, 1Mbps (1Mbps = 1 Mbit/s, 10 kbps = 10 kbit/s)