User Manual

Page 48
PSI 9000 2U Series
www.elektroautomatik.de
ea1974@elektroautomatik.de
EA Elektro-Automatik GmbH
Helmholtzstr. 31-33 • 41747 Viersen
Germany
Fon: +49 2162 / 3785-0
Fax: +49 2162 / 16230
3.3.3.5 Menu “About HW, SW...”
This menu page displays an overview of device relevant data such as serial number, article number etc.
3.3.3.6 Menu “Function Generator”
See „3.8 The function generator“ on page 61.
3.3.3.7 Menu “Communication”
Here settings for digital communication via the optional interface modules (abbr. IF) of the IF-AB series are made.
Thetoucharea“Congureinterface”opensoneormoresettingspages,dependingonthemoduleinuse.
For all Ethernet interfaces with two ports: „P1“ is related to port 1 and „P2“ to port 2, like printed
on the module face. Two-port interfaces will use one IP only.
IF Level 1 Level 2 Level 3 Description
Ethernet / ModBus-TCP, 1 & 2 Port
IP Settings DHCP The IF allows a DHCP server to allocate an IP address, a subnet
mask and a gateway. If no DHCP server is in the network then net-
workparameterswillbesetasdenedinitem“Manual”
Manual IP This option is activated by default. An IP address can be maually
allocated.
Gateway Here a gateway address can be allocated if required..
Subnet Hereasubnetmaskcanbedenedifthedefaultsubnetmaskis
not suitable.
DNS 1 HeretheaddressesoftherstandsecondDomainNameServers
(DNS)canbedened,ifneeded.ADNSisonlynecessaryifthe
device has Internet access and should call Internet URLs, e.g. an
internal eMail system, in order to send an eMail.
DNS 2
Port Range: 0...65535. Default ports:
5025 = Modbus RTU (all Ethernet interfaces)
502 = Modbus TCP (Modbus-TCP interface only)
IP Com
Settings P1
IP Com
Settings P2
AUTO Settings for the Ethernet port such as transmission speed are set
automatically.
Manual Half dup Manual selection for transmission speed (10MBit/100MBit) and
duplex mode (full/half). It is recommended to use the “AUTO” option
and only revert to “Manual” if these parameters fail.
Full dup
10MBit
100MBit
Host name Free choice of host name (default: Client)
Domain name Free choice of Domain (default: Workgroup)
SMTP
Settings
Server IP Mail server address, used to send eMails via this mail server, in
order to e.g. report an alarm.
Username Login to Mailserver, Username
Password Login to Mailserver, Password
IF Level 1 Description
Probus DP
Node Address SelectionoftheProbusornodeaddressofthedevicewithinrange1...125via
direct input
Function Tag Stringinputboxforauser-denabletextwhichdescribestheProbusslavefunction
tag. Max. length: 32 characters
Location Tag Stringinputboxforauser-denabletextwhichdescribestheProbusslavelocation
tag. Max. length: 22 characters
Installation Date Stringinputboxforauser-denabletextwhichdescribestheProbusslaveinstal-
lation date tag. Max. length: 40 characters
Description Stringinputboxforauser-denabletextwhichdescribestheProbusslave.
Max. length: 54 characters
IF Level 1 Description
RS232
- Therearenocongurableparametersforthismodule.Italwaysusestheseserial
settings: Baud rate = 115200 Baud, 8 data bits, 1 stop bit, parity = none