User Manual

Page 21
EA Elektro-Automatik GmbH
Helmholtzstr. 31-33 • 41747 Viersen
Germany
Fon: +49 2162 / 3785-0
Fax: +49 2162 / 16230
www.elektroautomatik.de
ea1974@elektroautomatik.de
PS 9000 2U Series
3000 W
Model 2U
PS 9360-30 PS 9500-20 PS 9750-12
Analog interface
(1
Set value inputs U, I, P U, I, P U, I, P
Actual value output U, I U, I U, I
Control signals
DC on/off,
Remote on/off
DC on/off,
Remote on/off
DC on/off,
Remote on/off
Status signals CV, OVP, OT CV, OVP, OT CV, OVP, OT
Galvanic isolation to the device Max. 1500 V DC Max. 1500 V DC Max. 1500 V DC
Insulation
Output (DC) to enclosure (PE)
DC minus: permanent max. 400 V
DC plus: permanent max. 400V + output voltage
Input (AC) to output (DC) Max. 2500 V, short-term
Miscellaneous
Cooling Temperature controlled fans, front inlet, rear exhaust
Ambient temperature 0..50°C
Storage temperature -20...70°C
Humidity < 80%, not condensing
Standards EN 61010, EN 61326
Overvoltage category 2
Protection class 1
Pollution degree 2
Operational altitude < 2000 m
Digital interfaces
Featured 1x USB-B, 1x Ethernet
Galvanic isolation from device Max. 1500 V DC
USBspecication USB 2.0, socket type B, VCOM driver
USB response time SCPI: max. 2 ms, ModBus: max. 2 ms
Ethernetspecication RJ45, 10/100Mbit, TCP/IP, ICMP, HTTP, DHCP
Ethernet response time SCPI: max. 7 ms, ModBus: 9-17 ms
Terminals
Rear side Share Bus, DC output, AC input, remote sensing, analog interface, USB-B, Ethernet
Dimensions
Enclosure (WxHxD) 19“ x 2U x 463 mm
Total (WxHxD) 483 x 88 x min. 535 mm (depending on DC out terminal type)
Weight ~ 15 kg ~ 15 kg ~ 15 kg
Article number 06230216 06230217 06230218
(1Fortechnicalspecicationsoftheanaloginterfacesee„3.4.4.3 Analog interface specication“ on page 50