15 kW
Model 3U
PS 9200-210 PS 9360-120 PS 9500-90 PS 9750-60 PS 91500-30
AC Input
Input voltage 340...460 V AC 340...460 V AC 340...460 V AC 340...460 V AC 340...460 V AC
Input connection 3ph,PE 3ph,PE 3ph,PE 3ph,PE 3ph,PE
Input frequency 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz
Input fuse (internal) 6x T16 A 6x T16 A 6x T16 A 6x T16 A 6x T16 A
Leak current < 3.5 mA < 3.5 mA < 3.5 mA < 3.5 mA < 3.5 mA
Power factor > 0.99 > 0.99 > 0.99 > 0.99 > 0.99
DC Output
Max. output voltage U
Max
200 V 360 V 500 V 750 V 1500 V
Max. output current I
Max
210 A 120 A 90 A 60 A 30 A
Max. output power P
Max
15 kW 15 kW 15 kW 15 kW 15 kW
Voltage regulation
Adjustment range 0...200 V 0...360 V 0...500 V 0...750 V 0...1500 V
Overvoltage protection range 0...220 V 0...396 V 0...550 V 0...825 V 0...1650 V
Accuracy
(1
< 0.1% U
Max
< 0.1% U
Max
< 0.1% U
Max
< 0.1% U
Max
< 0.1% U
Max
Stabilityat±10%ΔU
AC
< 0.02% U
Max
< 0.02% U
Max
< 0.02% U
Max
< 0.02% U
Max
< 0.02% U
Max
Stability at 0...100% load < 0.05% U
Max
< 0.05% U
Max
< 0.05% U
Max
< 0.05% U
Max
< 0.05% U
Max
Rise time 10...90% Max. 30 ms Max. 30 ms Max. 30 ms Max. 30 ms Max. 30 ms
Display: Resolution See section „1.10.6.4. Resolution of the displayed values“
Display: Accuracy
(4
≤0.2%U
Max
≤0.2%U
Max
≤0.2%U
Max
≤0.2%U
Max
≤0.2%U
Max
Ripple
(2
< 250 mV
PP
< 25 mV
RMS
< 350 mV
PP
< 50 mV
RMS
< 300 mV
PP
< 70 mV
RMS
< 700 mV
PP
< 120 mV
RMS
< 1000 mV
PP
< 350 mV
RMS
Remote sensing compensation Max. 5% U
Max
Max. 5% U
Max
Max. 5% U
Max
Max. 5% U
Max
Max. 5% U
Max
Fall time at no load after switching
DC output off
Down from 100% to <60 V: less than 10 s
Current regulation
Adjustment range 0...210 A 0...120 A 0...90 A 0...60 A 0...30 A
Overcurrent protection range 0...231 A 0...132 A 0...99 A 0...66 A 0...33 A
Accuracy
(1
< 0.2% I
Max
< 0.2% I
Max
< 0.2% I
Max
< 0.2% I
Max
< 0.2% I
Max
Stabilityat±10%ΔU
AC
< 0.05% I
Max
< 0.05% I
Max
< 0.05% I
Max
< 0.05% I
Max
< 0.05% I
Max
Stabilityat0...100%ΔU
OUT
< 0.15% I
Max
< 0.15% I
Max
< 0.15% I
Max
< 0.15% I
Max
< 0.15% I
Max
Ripple
(2
< 167 mA
PP
< 33 mA
RMS
< 132 mA
PP
< 19 mA
RMS
< 50 mA
PP
< 23 mA
RMS
< 61 mA
PP
< 11 mA
RMS
< 19 mA
PP
< 13 mA
RMS
Display: Resolution See section „1.10.6.4. Resolution of the displayed values“
Display: Accuracy
(4
≤0.2%I
Max
≤0.2%I
Max
≤0.2%I
Max
≤0.2%I
Max
≤0.2%I
Max
Compensation 10%->90% load < 2 ms < 2 ms < 2 ms < 2 ms < 2 ms
Power regulation
Adjustment range 0…15.00 kW 0…15.00 kW 0…15.00 kW 0…15.00 kW 0…15.00 kW
Overpower protection range 0…16.50 kW 0…16.50 kW 0…16.50 kW 0…16.50 kW 0…16.50 kW
Accuracy
(1
< 1% P
Max
< 1.2% P
Max
< 1.2% P
Max
< 1.2% P
Max
< 1.2% P
Max
Stabilityat±10%ΔU
AC
< 0.05% P
Max
< 0.05% P
Max
< 0.05% P
Max
< 0.05% P
Max
< 0.05% P
Max
Stabilityat10-90%ΔU
OUT
*ΔI
OUT
< 0.75% P
Max
< 0.75% P
Max
< 0.75% P
Max
< 0.75% P
Max
< 0.75% P
Max
Display: Resolution See section „1.10.6.4. Resolution of the displayed values“
Display: Accuracy
(4
≤0.8%P
Max
≤0.85%P
Max
≤0.85%P
Max
≤0.85%P
Max
≤0.85%P
Max
Efciency
(3
~ 95% ~ 94% ~ 95% ~ 94% ~ 95%
(1Relatedtothenominalvalues,theaccuracydenesthemaximumdeviationbetweenanadjustedvaluesandthetrue(actual)value.
Example: a 80 V model has min. 0.1% voltage accuracy, that is 80 mV. When adjusting the voltage to 5 V, the actual value is allowed to differ max. 80 mV, which
means it might be between 4.92 V and 5.08 V.
(2 RMS value: LF 0...300 kHz, PP value: HF 0...20MHz
(3 Typical value at 100% output voltage and 100% power
(4 The display accuracy adds to the general accuracy, so the error (i.e. deviation) will be higher.