User Manual
Doc ID: BSEN
Date: 07-15-19
Page 9
5.2.3 Status 2
Baery and simulaon status share two areas. The right-hand
area shows the simulated baery temperature and the calcu-
lated internal resistance.
Before the simulaon is started, the indicated baery temperature will be idencal to the one in the setup below, but will change
during runme. Same for the internal resistance.
5.2.4 Control
Control, i. e. manual start and stop of the simulaon, is done
via two buons in the upper part of the main window.
Aer the start of the soware the Start buon is locked unl
the simulaon has been inialized (Inialize buon).
Following rules for control:
• Baery simulaon could be interrupted by a device alarm or disconnecon, but can be connued later
• You can manually Stop anyme and then connue the test (Start buon)
• The simulaon would only start from the very beginning when reseng the test to its start condions with buon Inialize
• The Start buon will be locked unl inializaon
5.3 Tab “Baery Simulator”
The lower part of the main window, specically tab “Baery Simulator” is most important. There you set up your simulaon pa-
rameters. The sum of all sengs can be saved in conguraon proles (CSV le) and loaded at will. The latest saved set of sengs
can also be loaded automacally, if opon “Load conguraon at startup” is checked.
Overview:
Figure 4 - Baery Simulator tab
Nr Parameter Descripon
1 Baery type
This selector is usually locked to the baery type dened by the license on the USB dongle. It means, the
soware will detect the kind of license and automacally select the baery type. Only if two dierent
license dongles are plugged to the same PC, this selector will be unlocked.
With date June, 2019 and when unlocked, it selects the simulated baery type between Lead-Acid and
Lithium-Ion. The selecon aects the adjustable range of parameters Capacity, Internal resistance, Voltage
lower cuto and Voltage upper cuto.