User Manual
Page 15
EA Elektro-Automatik GmbH
Helmholtzstr. 31-33 • 41747 Viersen
Germany
Fon: +49 2162 / 3785-0
Fax: +49 2162 / 16230
www.elektroautomatik.de
ea1974@elektroautomatik.de
ELR 9000 Series
(3 For technical specications of the analog interface see „3.4.4.2 Analog interface specication“ on page 50
10.5kW
Model
ELR 9080-510 ELR 9250-210 ELR 9500-90 ELR 9750-66 ELR 91500-30
Analog interface
(3
Set value inputs U, I, P U, I, P U, I, P U, I, P U, I, P
Actual value output U, I U, I U, I U, I U, I
Control signals
DC on/off,
Remote on/off
DC on/off,
Remote on/off
DC on/off,
Remote on/off
DC on/off,
Remote on/off
DC on/off,
Remote on/off
Status signals CV, OVP, OT CV, OVP, OT CV, OVP, OT CV, OVP, OT CV, OVP, OT
Galvanic isolation to the device max. 1500V DC max. 1500V DC max. 1500V DC max. 1500V DC max. 1500V DC
Programming (analog+digital)
Resolution: Voltage (U) 25mV 76mV 153mV 229mV 458mV
Accuracy: Voltage (U) ≤226mV ≤706mV ≤1413mV ≤2219mV ≤4239mV
Resolution: Current (I) 156mA 64 mA 28mA 21mA 9mA
Accuracy: Current (I) ≤1849mA ≤761mA ≤326mA ≤239mA ≤109mA
Resolution: Power (P) 12.5W 16W 14W 15W 14W
Accuracy: Power (P) ≤126W ≤144W ≤133W ≤140W ≤133W
Environment
Cooling Temperature controlled fans
Ambient temperature 0..50°C
Storage temperature -20...70°C
Digital interfaces
Featured 1x USB-B for communication, 1x USB-A for updates and functions
Slot for optional AnyBus modules CANopen, Probus, Pronet, RS232, Devicenet, Ethernet, ModBus
Terminals
Rear side
(3
Share Bus, DC input, AC input/output, remote sense, analog interface, USB-B,
master-slave bus, AnyBus module slot
Front side USB-A
Dimensions
Enclosure (WxHxD) 19“ x 3U x 609mm
Total (WxHxD) 483mm x 133mm x 714mm
Standards EN 60950, EN 50160 (grid class 2)
Weight 31kg 31kg 31kg 31kg 31kg
Article number 33200410 33200411 33200412 33200413 33200414